background image

EIS ENTRY-RX 

USER MANUAL

 

Page 8 

6

 

CONNECTION DIAGRAM 

Before connection the EIS please take a look at connection diagram. 

Figure 1: EIS: Connection diagram 

IMPORTANT 

DO  NOT  USE  Power  out  (12V  AUX)  for  electric  lock  driving!  Use  separate 
power source for door electric lock! 

Must use 15VDC power supply that is provided with EIS unit.

Summary of Contents for EIS ENTRY-CR

Page 1: ...EIS ENTRY RX USER MANUAL GSM REMOTE MOBILE SWITCH Programming Software v 1 4 2016 0816...

Page 2: ......

Page 3: ...START UP 6 5 LED INDICATION 7 6 CONNECTION DIAGRAM 8 7 EIS UNIT MANAGEMENT 9 8 EIS FUNCTIONS WITH PROGRAMMING INSTRUCTIONS 10 8 1 WEB SERVER LOG IN 10 8 2 WEB SERVER ADDING UNITS TO USER PROFILE 11 8...

Page 4: ...er Main page select ADD mode 11 Figure 4 WEB Server Main page adding EIS units 12 Figure 5 WEB Server Unit management window 13 Figure 6 WEB Server Caller ID Access 14 Figure 7 WEB Server Output setti...

Page 5: ...HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless devices can cause interference in aircraft SWITCH OFF WHEN REFUELIN...

Page 6: ...GSM switch system designed to ensure low cost simple to install use reliable and single box solution for remote managed switching application It is designed for unlimited range caller ID control Opti...

Page 7: ...lt in 5 band GSM module Caller ID numbers control up to 100 caller ID numbers 1 output relay supported Programming with PC via USB to Mini USB cable connected to the unit Programming by WEB server Pro...

Page 8: ...unit YOU MUST POWER THE EIS UNIT WITH THE POWER SUPPLY INCLUDED Do not power with any other power supply Power up the unit Wait until LED1 Green starts flashing This is set in around 30 45 seconds EI...

Page 9: ...of the GSM signal from 1 to 5 LED flashes 1 is weak signal 5 is excellent signal Yellow LED LED3 Short flashing indicates that the GSM module is ON but it is not yet connected on the GSM network After...

Page 10: ...nnection the EIS please take a look at connection diagram Figure 1 EIS Connection diagram IMPORTANT DO NOT USE Power out 12V AUX for electric lock driving Use separate power source for door electric l...

Page 11: ...ifferent types of management programming Unit can be programmed directly by USB connection with the use of configuration software running on PC EIS Ware Unit can be programmed remotely by using WEB se...

Page 12: ...ay WEB programming IMPORTANT SIM card in the EIS unit MUST have DATA PLAN to be able to use WEB programming 8 1 WEB SERVER LOG IN The web server can be find under the address http www eisware com Figu...

Page 13: ...2 WEB SERVER ADDING UNITS TO USER PROFILE After login the user will be diverted to WEB server main window This page is used to add remove search for EIS units from the user s profile Select sign to s...

Page 14: ...be on the card board box of the EIS Phone Number The telephone number of the SIM card in the EIS unit mandatory data GPRS settings Information needed to enable data connection between the server and...

Page 15: ...e the configuration of the specific unit All changes made by the user are listed in the Change Log window By clicking Send to device button ALL changes are send to the unit User can revert all changes...

Page 16: ...r ID Disabled deactivates caller ID function all numbers are restricted Caller ID for specific users will limit the caller ID function only to the numbers on the list Caller ID always ON will allow al...

Page 17: ...nt will activate the output second Caller ID event will deactivate the output Time Pulse Output is time pulse mode After output is triggered it will be activated for the time defined in Output pulse d...

Page 18: ...authorized call or SMS received If unauthorized call or SMS is received on the unit this event will activate output defined under this section Input 1 activate output If input 1 is activated this acti...

Page 19: ...er User name Phone number and user name of the user that will be receiving notification messages Input1 If on input line 1 alarm condition is meet users with check boxes will receive alarm notificatio...

Page 20: ...uthorized call the unit can notify user To enable notification SMS tick the check box in corresponding position Administration allowed to remote program by SMS By selection this option the user can Lo...

Page 21: ...l User can select GSM module restart interval hours if needed Not advisable to use this parameter if not advised otherwise Self updating clock Parameter is used to allow unit to synchronize to real ti...

Page 22: ......

Page 23: ...TABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE...

Reviews: