9.2 Door setting (continued)
Anti-Pass Back Settings
Anti-Pass back Disabled (Factory default)
Anti-Pass back Master Mode:
Anti-Pass back Auxiliary Machinery Mode
(Note: the detailed wiring diagram and
illustration, please refer to the “Advanced
application”
3 0 #
3 1 #
3 2 #
Door open detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic
contact or built-in magnetic contact of the lock, if the door is opened normally, but
not closed after 1 minute, the inside buzzer will beep automatically to remind
people to close the door and continue for 1 minute before switching off
automatically.
Door Forced Open warning. When used with an optional magnetic contact or built in
magnetic contact of the lock, if the door is forced open, or if the door is opened
after 120 seconds of the electro-mechanical lock not closed properly, the inside
buzzer and alarm output will both operate.
To disable door open detection.
(Factory default)
6 0 #
To enable door open detection
6 1 #
Security Mode Setting
Reader Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect
PIN numbers in a 10 minute period either the reader will lockout for 10 minutes or the
alarm will operate for 10 minutes, depending on the option selected below.
Normal status (No lockout or Alarm)
7 0 # (Factory default setting)
Keypad Lockout
7 1 #
Alarm Output
7 2 #
Alarm output time
To set the alarm output time (0-3
minutes) Factory default is 1 minute
9 0 3 #
To remove the alarm
To remove the Door Forced Open warning
Read valid card or Master Code#
To remove the Door Open Too Long
warning
Close the door or Read valid card or Master Code #
8