EA002 2 / 10 / 50 CLAMP COIL ADAPTER 

OPERATION MANUAL 

Transmille Ltd.  

Page 9 

 Care & Maintenance 

 

The only maintenance instructions for the adapter is periodic cleaning.  

See below for details on the cleaning procedure and precautions for handling. 

Cleaning the Adapter 

 

To keep the external enclosure of the adapter in good condition, clean the outer case with 

a soft cloth. Do not use any liquids in cleaning the enclosure – removal of surface dust is 

all that is recommended. 

 

CAUTION 

 

Do not use cleaning fluids or solvents for cleaning as these may damage the  

enclosure and affect the plastic materials used in the adapter. 

Handling Precautions 

The adapter is designed for mechanical stability, but should not be subjected to excessive 

shock or be dropped. Transportation is recommended using the original packaging with 

avoidance of extreme changes of temperature. 

Servicing Information 

The adapter is provided certified from the factory, and uses precision components and are 

not user repairable. If the adapter is damaged it should be returned to the factory for repair 

and recalibration. 

Summary of Contents for EA002

Page 1: ...EA002 2 10 50 TURN 1500A CLAMP COIL ADAPTER OPERATION MANUAL...

Page 2: ...Version 1 00 April 2007 All product names are trademarks of their respective companies EA002 2 10 50 Clamp Coil Adapter Operation Manual...

Page 3: ...by the purchaser Transmille will contact the purchaser before proceeding with any repair To obtain repair under this guarantee the purchaser must send the instrument in its original packaging carriag...

Page 4: ...Terminals to 10 Turn Coil Up to 20A simulation using coil 7 3000 Series 30A Terminals to 10 Turn Coil Up to 300A simulation using coil 7 3000 Series 2A Terminals to 50 Turn Coil Up to 100A simulation...

Page 5: ...by the number of turns of the coil e g 2 10 and 50 with the Transmille coil The principle is each turn of the coil produces a magnetic field proportional to the current flowing in it If you take 50 w...

Page 6: ...total accuracy which should be taken into account when calibrating clamp meters using a coil The first is the accuracy of the current produced by the calibrator the second is the coupling between the...

Page 7: ...MANUAL Transmille Ltd Page 6 2 Turn Coil Minimum 10mm inside jaw diameter 10 Turn Coil Minimum 10mm inside jaw diameter 50 Turn Coil Minimum 25 4mm inside jaw diameter Connection Diagrams Terminal Co...

Page 8: ...Page 7 3000 Series 2A Terminals to 10 Turn Coil Up to 20A simulation using coil 3000 Series 30A Terminals to 10 Turn Coil Up to 300A simulation using coil 20A output 200A Simulation for 3050 3000 Seri...

Page 9: ...s 30A Terminals to 50 Turn Coil Up to 1500A simulation using coil 20A output 1000A Simulation for 3050 3000 Series 2A Terminals to 2 Turn Coil Up to 4A simulation using coil 3000 Series 30A Terminals...

Page 10: ...s all that is recommended CAUTION Do not use cleaning fluids or solvents for cleaning as these may damage the enclosure and affect the plastic materials used in the adapter Handling Precautions The ad...

Page 11: ...EA002 2 10 50 CLAMP COIL ADAPTER OPERATION MANUAL Transmille Ltd Page 10 EA002 2 10 50 Clamp Coil Adapter Appendix A Specifications...

Page 12: ...0 41 0 01 0 41 0 01 Effective accuracy Coil only hall effect clamps 0 59 0 11 0 59 0 11 0 59 0 11 0 59 0 11 Total uncertainty with 3050 All clamps 0 61 0 13 0 62 0 13 0 62 0 13 0 65 0 14 Total uncerta...

Page 13: ...il Only 120uH Coil with typical clamp meter on 50 Turn coil 200uH Coil with typical clamp meter on 10 Turn coil 50uH Coil with typical clamp meter on 2 Turn coil 5uH Specifications apply between 17 C...

Reviews: