background image

CARE OF THE TIP

 

The tip supplied is plated copper and will last a long time. Please observe the following conditions: 
 

1.  Always  keep  the  tip  tinned  before  switching  off  or  storing  for  any  period  of  time,  wipe  only 

before use. 

2.  Do not keep the iron set at a high temperature for long periods of time as this will break down 

the surface of the tip. 

3.  Never clean the tip with a file or coarse abrasive materials. 
4.  If, however, an oxide film does form on the tip, it can be cleaned by lightly rubbing with a 600-

800  grit  emery  cloth,  isopropyl  alcohol  or  equivalent.  Once  this  is  done,  immediately  reheat 
and re-tin the tip to prevent further oxidation. 

5.  If  used  continuously,  remove  the  tip  and  clean  every  twenty  hours,  or  at  least  once  a  week. 

Also, remove any loose build up that may appear in the barrel. 

6.  Do not use fluxes containing chlorides or acids. Use only rosin or activated resin fluxes. 
7.  Do not use any anti-seize materials or compounds on the wettable surface of the tip. 

 
 
 
 

MAINTENANCE 

 

The soldering iron must be placed on the stand when not in use. 
 
If the supply cord is damaged in any way it must be replaced immediately in order to avoid a hazard. A 
suitably qualified person or service agent must carry this out. 
 

TIP REPLACEMENT AND DRESSING

 

Note: Tip replacement or cleaning should be done only when the iron is at room temperature. The tip 

can be changed or replaced simply by unscrewing the knurled nut barrel assembly. It is essential that 
the station be switched off and allowed to cool before and during this operation, as damage may result 
if the system is left on without the tip inserted. 
After removing the tip, blow out any  oxide dust that  may have formed in the tip  retaining area of the 
barrel. 
Care should be exercised to avoid getting dust  in  your eyes.  Replace  the  tip and tighten the knurled 
nut  barrel  assembly  using  only  hand  pressure.  Pliers  should  only  be  used  to  tighten  the  nut,  as  this 
may damage the element.  
 

GENERAL CLEANING

 

The outer case of the iron or station may be cleaned with a damp cloth using small amounts of liquid 
detergent. Never submerse the unit in liquid or allow any liquid to enter the case of the station. Never 
use solvents to clean the case.  