Transition
Networks
E
‐
100BTX
FX
06
User
Guide
33791
Rev.
A
http://www.transition.com/
Page
3
of
13
Family
Portrait
Page 1: ...onverter 6 Operation 6 Status LEDs 6 Auto Negotiation 6 Pause Control 6 Auto MDI MDIX 6 Active Link Pass Through ALPT 7 Far End Fault 8 Specifications 8 Cable Specifications 8 Technical Specifications...
Page 2: ...20 km 12 4 miles Typical maximum cable distance Actual distance depends on the physical characteristics of the network installation For more information see https www transition com Accessories Access...
Page 3: ...Transition Networks E 100BTX FX 06 User Guide 33791 Rev A http www transition com Page 3 of 13 Family Portrait...
Page 4: ...IP Switch The 4 position DIP switch is located on the side of the media converter Use a small flat blade screwdriver or a similar tool to set the recessed switches 1 Auto Negotiation Up Enables Auto N...
Page 5: ...tor to the female RX port 3 Connect the fiber cables to the other device another media converter Ethernet Switch etc as described Connect the male TX cable connector to the female RX port Connect the...
Page 6: ...is being received on the copper link RXF Receive Fiber Flashing A signal is being received on the fiber link Auto Negotiation When the Auto Negotiation feature is activated the media converter config...
Page 7: ...is met Upon power up of the converter Upon losing Link on either the copper or fiber ports In the Diagnostic state the link for each of the media converter s ports can come up independently of each o...
Page 8: ...3 and 4 Specifications The fiber optic cable physical characteristics must meet or exceed IEEE 802 3ae specification Cable Specifications The physical characteristics must meet or exceed IEEE 802 3 s...
Page 9: ...ultimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dbm E 100BTX FX 06 SM 1310 nm single mode Fiber optic Trans...
Page 10: ...cUL Listed Canada FCC Part 15 Class A EN 55032 2012 EN 55024 2010 Directive 2014 30 EU Low Voltage Directive 2014 35 EU IEC EN 60950 1 2006 A2 2013 2011 65 EU EN 50581 2012 CE Mark MTBF Greater than...
Page 11: ...t Tech Support See Contact Us on page 18 below YES Proceed to step 3 3 Is the SDF LED signal detect fiber illuminated NO Check the fiber cables for proper connection Verify that the TX and RX cables o...
Page 12: ...y US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 sales transition com techsupport transition com customerservice...
Page 13: ...eses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F ll is der Benutzer f r Gegenma nahmen verantwortlich Attenti...