Install Cable
COPPER
1.
Locate or build cables that are compliant with
specifications in this document.
2.
Connect 26-pin connector at one end of cable to media
converter 26-pin copper connector.
CAUTION: Ensure that cable screwlocks are tightened
securely. Failure to observe this caution could cause
data transfer to fail.
3.
Connect RJ-45 plug connector at other end of cable to
network equipment.
FIBER
1.
Locate or build fiber cables that are compliant with
specifications in this document, with male two-stranded
TX to RX connectors installed at both ends.
2.
Connect cable with connector installed at TX location
on media converter to RX location on attached device.
3.
Connect cable with connector installed at RX location
on media converter to TX location on attached device.
Set Terminal Timing Switch
NOTE: The sixteen-position Terminal Timing switch, located at the
SPSVT29xx-100 media converter side, allows the network
administrator to configure the media converter for network
conditions.
Insert small flatblade screwdriver or similar device into recessed
arrow on Terminal Timing switch, then gently rotate switch to the
position required for the site installation.
Refer to table below for switch position key.
Terminal Timing Switch Settings
10
7
0 – TT = Receive CLK
1 – 56 Kb/s
2 – 64 Kb/s
3 – 112 Kb/s
4 – 128 Kb/s
5 – 256 Kb/s
6 – 384 Kb/s
7 – 512 Kb/s
8 – 768 Kb/s
9 – 1024 Kb/s
A – 1544 Kb/s
B – 2048 Kb/s
C – 3072 Kb/s
D – 4096 Kb/s
E – 6144 Kb/s
F - Asynchronous mode