![Transition Networks SISTF1011-130-LR User Manual Download Page 8](http://html1.mh-extra.com/html/transition-networks/sistf1011-130-lr/sistf1011-130-lr_user-manual_1152218008.webp)
14
SISTF10xx-130-LR(T)
24-hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
Troubleshooting
If the device fails, isolate and correct the fault by determining the answers to the
following questions and then taking the indicated action:
1.
Is the PWR1 LED illuminated?
NO
•
Ensure the power source is the proper voltage (12 - 48 VDC).
•
Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR1”.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the PWR2 LED illuminated?
NO
•
Ensure the power source is the proper voltage (12 - 48 VDC).
•
Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR2”.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the FAULT LED illuminated?
YES
•
If one or more port alarm switches (1 - 5) is
ON
,
the device lost the
corresponding fiber or copper link; or primary or backup power.
•
Ensure the problem copper or fiber link is properly connected.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 4.
4.
Is the Ring Master LED flashing?
YES
•
A link in the Redundant Ring is broken. Inspect the fiber links in the
ring for proper connection.
•
Verify that the TX and RX cables on one device are connected to the
RX and TX ports, respectively, on the adjacent device.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 5.
5.
Are either 100M LEDs (near the fiber links) illuminated?
NO
•
Check the corresponding fiber cables for proper connection.
•
Verify that the TX and RX cables on the device are connected to the
RX and TX ports, respectively, on the other device.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 6.
Troubleshooting
-- Continued
6.
Are either 100M LEDs (near the fiber links) flashing?
NO
•
If there is activity on the corresponding fiber port, disconnect and
reconnect the fiber cable to restart the initialization process.
•
If there is no activity on the corresponding fiber port, contact Tech
Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 7.
7.
Are any of the 10M LEDs (on the RJ-45 port) illuminated?
YES
•
The device has selected 10 Mb/s for the twisted-pair link.
•
If the speed is not correct, disconnect and reconnect the twisted-pair
cable to restart the initialization process.
•
Proceed to step 8.
NO
•
Proceed to step 8.
8.
Are any of the 100M LEDs (on the RJ-45 port) illuminated?
YES
•
The device has selected 100 Mb/s for the twisted-pair link.
•
If the speed is not correct, disconnect and reconnect the twisted-pair
cable to restart the initialization process.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Check the twisted-pair cables for proper connection.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
-- Click the
“Transition Now”
link for a live Web chat.
15
Declaration of Conformity
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344, USA
Model:
SISTF10xx-130-LR(T) Series Redundant Ring Industrial Switches
Part Number(s):
SISTF1011-130-LR, SISTF1012-130-LR, SISTF1013-130-LR,
SISTF1014-130-LR, SISTF1011-130-LRT, SISTF1012-130-LRT,
SISTF1013-130-LRT, SISTF1014-130-LRT
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the
SISTF10xx-130-LR(T)
to which this declaration refers
is in conformity with the following standards.
EN 55022:1998 Class A; FCC Part 15 Subpart B; 21CFR subpart J;
UL 60950; UL 508; CSA C22.2 no 60950; EN 60950;
UL/cUL Class 1, Div 2, Groups A, B, C, D; ATEX Class 1, Zone 2, EExnC IIC;
EN61000-4-2, -4-3, -4-4, -4-5, -4-6; IEC 60068-2-6, -2-27, -2-32
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
_
December 3, 2004_____
Stephen Anderson, Vice-President of Engineering
Date
NOTE:
The following part numbers are UL listed: SISTF1013-130-LR, SISTF1013-130-
LRT, SISTF1014-130-LR, SISTF1014-130-LRT