background image

 

 

Section VI: 

Contact Us, Warranty, &  

Compliance Information  

 

 

Introduction 

This section explains how to contact Transition Networks via Phone, fax, email, and direct 
mail.  It also explains: 

  What the warranty covers  

  Who to contact to return product 

  How and where to return the product 

  Industry standards compliance 

  

In this section 

These are the topics: 

 

Topic 

See Page 

Contact us 

25 

Warranty 

26 

Compliance information 

28 

  

Summary of Contents for SISTF1010-180-LR

Page 1: ...SISTF1010 180 LR T 10 100Base TX Industrial Unmanaged Switch Installation Manual Rev A 6 July 2007...

Page 2: ......

Page 3: ...tents 4 Package contents 4 Physical description 5 Physical dimensions 5 Front panel 5 Bottom panel 6 Back panel 6 Section II 7 Installation 7 In this section 7 DIN rail mounting 8 DIN rail clip 8 DIN...

Page 4: ...4 Introduction 24 In this section 24 Contact us 25 Technical support 25 Live Web chat 25 Web based training 25 E Mail 25 Address 25 Warranty 26 Limited lifetime warranty 26 What the warranty does not...

Page 5: ...nd to comply with the limits for class A devices pursuant to part 15 of FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation T...

Page 6: ...this manual This manual provides instructions on how to install configure and operate the SISTF1010 180 LR T 10 100Base TX Industrial Unmanaged Switch Manual structure This manual has a beginning tabl...

Page 7: ...les CAUTION Only qualified persons should install the Industrial Switch Failure to observe this caution could result in poor performance or damage to the Industrial Switch CAUTION Install the Industri...

Page 8: ...nued Warnings Warnings indicate the possibility of injury to persons WARNING Be sure to disconnect power before installing and wiring the Industrial Switch Failure to observe this warning could result...

Page 9: ...TF1010 180 Industrial Unmanaged Switch In this section These are the topics Topic See Page General description 2 SISTF1010 180 Industrial Unmanaged Switch model numbers 3 Package Contents 4 Physical D...

Page 10: ...ature ranges Standard 0 C to 60 C 32 F to 140 F Extended 40 C to 75 C 40 F to 167 F Features The SISTF1010 180 Industrial Unmanaged Switch has the following features Auto Negotiation AutoCross TM Dual...

Page 11: ...umber Ports 1 8 10 100Base TX SISTF1010 180 LRT RJ 45 100 m 328ft Note The distances for ports 1 and 2 listed in Tables 1 and 2 are typical maximum distances the physical characteristics of the networ...

Page 12: ...ndustrial Unmanaged Switch 1 DIN Rail mounting bracket installed 1 One wall mount plate 6 Screws for attaching wall mount bracket 1 Installation manual CD 1 Barrel connector interface cable For extern...

Page 13: ...e 1 with corresponding descriptions listed below Figure 1 SISTF1010 180 LR T Industrial Switch Front View Continued on next page 10 100Base TX UTP ports RJ 45 10 100Base TX UTP ports RJ 45 Terminal bl...

Page 14: ...Figure 2 with corresponding descriptions listed below Figure 2 SISTF1010 180 LR T Industrial Switch Bottom View Back panel The back view of the Industrial Switch is shown in Figure 3 with correspondi...

Page 15: ...n this section These are the topics Topic See Page DIN rail mounting 8 Wall mounting 10 Grounding the Industrial Switch 11 Connecting power to the Industrial Switch 12 Connecting copper cable 16 Light...

Page 16: ...face and attaching the Industrial Switch The surface must support at least 635g 1 4 lbs for the Industrial Switch Do not place heavy objects on the Industrial Switch CAUTION Mount the Industrial Switc...

Page 17: ...DIN rail mounting To mount the Industrial Switch to the DIN rail see Figure 5 and do the following Step Action 1 Align and then position DIN Rail clip spring to the top of the DIN rail as shown in Fi...

Page 18: ...trial Switch Wall mount bracket install To install the wall mount bracket to the Industrial Switch see Figure 6 and do the following Step Action 1 Remove existing screws 3 and DIN Rail bracket from re...

Page 19: ...the wires are perpendicular at the intersection point Use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is wiring that shares simila...

Page 20: ...TANT Power is supplied through an external 12 48 VDC power source Check the Technical Specification section for details about the DC power input voltage The Industrial Switch does not include a power...

Page 21: ...tructed keyed to mate with the Industrial Switch terminal block When wiring the plug for power use the polarity markings next to the terminal block and on top of the plug to ensure proper connection S...

Page 22: ...continued Step Action 6 Insert the terminal block plug into the Industrial Switch s terminal block as shown in Figure 10 Figure 10 Wired Terminal Block Plug Inserted Into Industrial Switch 7 Make sure...

Page 23: ...device For example SISTF1010 180 LRT 40 C to 75 C operating temp used with SPS UA12DHT xx 25 C to 70 C operating temp Operating temp for combination is 25 C to 70 C Step Action 1 Locate the barrel int...

Page 24: ...e RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation PLC etc 4 Check the copper port LED on the Industrial Switch to verify the connection LNK ACT L...

Page 25: ...er inputs PWR1 Green input power present on PWR1 input PWR2 Green input power present on PWR2 input LNK ACT UTP port 7 8 Green copper link Green blinking UTP port is receiving link pulses or data from...

Page 26: ...dvanced Features Introduction This section provides an explanation of the advanced features on the Industrial Switch In this section These are the topics Topic See Page AutoCross TM 19 Auto Negotiatio...

Page 27: ...0Mbps and duplex half full capabilities to other devices and negotiate the best mode of operation between the two devices No user intervention required to determine best mode of operation Optimal link...

Page 28: ...Switch 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 20 Section IV Cable Specifications Introduction This section provides copper cable specifications In this section These...

Page 29: ...to link up regardless of the cable configuration allowing either straight through MDI or crossover MDI X cables to be used Requires no operator intervention See Advanced Features section for more info...

Page 30: ...trial Switch via a problem and corrective action table The problems are stated in the problem column and the action s to take for the problem is stated in the corrective action column If the correctiv...

Page 31: ...lug into the Industrial Switch s terminal block See pages 12 16 Industrial Switch does not power up Is the power LED lit Check that DC power is at the recommended levels Contact Technical Support US C...

Page 32: ...t Transition Networks via Phone fax email and direct mail It also explains What the warranty covers Who to contact to return product How and where to return the product Industry standards compliance I...

Page 33: ...tworks Technical Support Specialist Log onto www transition com and click the Transition Now link Web based training Transition Networks provides 8 10 seminars per month via live web based training Lo...

Page 34: ...equivalent functional product Refund the purchase price of a defective product Who to contact for returns To return a defective product for warranty coverage contact Transition Networks technical sup...

Page 35: ...orization of repair If no authorization is obtained or the product is deemed not repairable Transition Networks will retain the 200 service charge and return the product to the customer not repaired R...

Page 36: ...will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on t...

Page 37: ...n for this activity can be found in the Contact Us portion of this document CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could...

Page 38: ...D CTS RTS DTR DSR RI DCD GND MAC Addresses 2K MAC address table Memory Buffer 1MB Transfer Rate 14 880 pps 10Mb or 148 800 pps 100Mb Packet Throughput 1 19Mpps 64bytes 8TX Back plane 1 6 Gbps Power Co...

Page 39: ...t the date of manufacture IMPORTANT Copper based media ports e g Twisted Pair TP Ethernet USB RS 232 RS422 RS485 DS1 DS3 Video Coax etc are intended to be connected to intra building inside plant link...

Reviews: