![Transition Networks SI-IES-1200-LRT User Manual Download Page 18](http://html.mh-extra.com/html/transition-networks/si-ies-1200-lrt/si-ies-1200-lrt_user-manual_1151337018.webp)
Transition Networks
SI-IES-1200-LRT User Manual
33586 Rev. D
https://www.transition.com
Page
18
of
21
Troubleshooting
□
Verify that you are using the right power cord and adapter. Do not use a power adapter with DC
outputs higher than the power rating of this equipment, or damage will occur.
□
Select the proper UTP/STP cable for your network. Please check that you are using the right cable.
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for the RJ-45 connections:
100Ω Category 3, 4, or 5 cable for 10Mbps connections or 100Ω Category 5 cable for 100Mbps
connections.
□
Be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
Diagnosing LED Indicators
□
The device can be easily monitored via LED indicators, which describe common problems you may
encounter and where the user can find possible solutions.
□
If the power LED does not light when the power cord is plugged in, you may have a problem with
power cord. Check for loose power connections, power losses or surges at the power outlet. If you
still cannot resolve the problem, contact your local dealer for assistance.
□
If the cables are properly connected and the LEDs show normal operation but data cannot
transmitted, check your system Ethernet devices configuration and status.
Service
Contact Us
Technical Support
: Technical support is available 24-hours a day
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Main Office
tel: +1.952.941.7600 | toll free: 1.800.526.9267 | fax: 952.941.2322
|
|
Address
Transition Networks
10900 Red Circle Drive
Minnetonka, MN 55343, U.S.A.
Web
:
https://www.transition.com