background image

Transition Networks 

 

SI-IES-1200-LRT User Manual 

33586 Rev. D 

https://www.transition.com

  

Page 

1

 of 

21

 

 

SI-IES-1200-LRT  

 

Hardened Gigabit PoE/PoE+ Injector

 

 

User Manual 

 

 

 

 

PN 33586 Rev. D  

 

 

 

Summary of Contents for SI-IES-1200-LRT

Page 1: ...Transition Networks SI IES 1200 LRT User Manual 33586 Rev D https www transition com Page 1 of 21 SI IES 1200 LRT Hardened Gigabit PoE PoE Injector User Manual PN 33586 Rev D ...

Page 2: ...mply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the in...

Page 3: ...el 7 Top View 8 Grounding the PoE Injector 8 Wiring the Power Inputs 9 RJ 45 Pin Assignments 10 10 100Base TX Cable Schema 11 10 100 1000Base T Pinouts 11 10 100 1000Base T Cable Schema 12 Power Supply Specifications 13 25130 Features and Specifications 13 25130 Dimensions 14 Installation 15 DIN Rail Mounting 15 Mounting the PoE Injector 16 Wall Mount Plate Mounting 17 Troubleshooting 18 Diagnosin...

Page 4: ...s outdoor enclosures or other challenging environments Introduction The SI IES 1200 LRT is a Hardened Gigabit PoE PoE Injector that provides data and DC power through the Ethernet cable to PoE equipped devices such as an IP camera access point PoE splitter or other equipment supporting IEEE 802 3af IEEE802 3at The SI IES 1200 LRT is typically installed near the Ethernet switch The figure below pro...

Page 5: ...24 48VDC Power Consumption 33 36 Watts 24 VDC 3 53 Watts No PoE 33 36 Watts 1 port PoE Operating Temp 40 C 75 C 40 F 167 F Storage Temp 40 C 85 C 40 F 185 F Humidity 5 95 Humidity non condensing Operating Storage Weight 1 3 lbs 0 59 kg EMC CE FCC Class A EN61000 6 4 EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS EN61000 4 8 Magnetic Field Safety UL508 M...

Page 6: ...jector One Wall mounting Kit One DIN rail mounting clip One Documentation Postcard Optional Accessories sold separately Industrial Power Supply 25130 Input 85 264VAC 120 370VDC Output 48VDC 83A 39 8 Watts Hardware Description Dimensions The Power over Ethernet Injector dimensions are Width 1 2 30 mm x Depth 3 7 95 mm x Height 5 5 140 mm ...

Page 7: ...three LED indicators LAN port RJ 45 Ethernet port used to connect to the existing Ethernet network PoE port RJ 45 Ethernet port capable of supplying power over the Ethernet cable and providing an Ethernet connection to powered devices P1 P2 The LED indicators light up when their respective power inputs are active PoE This LED indicator lights up when PoE power is being delivered ...

Page 8: ...input power in the range of 24 to 48V Grounding the PoE Injector Follow the instructions below to attach the PoE Injector to ground Attention When installing the PoE Injector the ground connection must always be made first and disconnected last 1 On the top of the device locate and remove the dome screw which has a ground symbol beside it 2 Attach the ground wire to the device enclosure with the d...

Page 9: ...r range 4 Insert the exposed wires into the terminal block plugs Only wires with insulation should extend from the terminal block plugs Note that the polarities between the wires and the terminal block plugs must be positive to positive and negative to negative 5 Use a slotted screwdriver to tighten the captive screws ATTENTION Use Copper Conductors Only At 60 75 C tighten to 5 lb in The wire gaug...

Page 10: ...ng straight through or crossover cabling See the figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note the and signs represent the polarity of the wires that make up each wire pair The table below shows the 10Base T 100Base TX MDI and MDI X port pinouts Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD T...

Page 11: ...se T Pinouts The table below describes the gigabit Ethernet RJ 45 pinouts Pin Signal Name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5 BI_DC Bi directional pair C 6 BI_DB Bi directional pair B 7 BI_DD Bi directional pair D 8 BI_DD Bi directional pair D ...

Page 12: ...Transition Networks SI IES 1200 LRT User Manual 33586 Rev D https www transition com Page 12 of 21 10 100 1000Base T Cable Schema The following two figures illustrate the 10 100 1000Base T cable schema ...

Page 13: ...Range 48 56VDC Voltage Tolerance 1 0 Line Regulation 1 0 Load Regulation 1 0 Setup Rise Time 500ms 30ms Hold Up Time 20ms 115VAC Input Voltage Range Switch Selectable 88 264VAC 120 370VDC Frequency Range 47 63Hz Efficiency 88 AC Current Typical 1 1A 115VAC 0 7A 230VAC Inrush Current Cold 30A 115VAC 60A 230VAC Leakage Current 1mA 240VAC Protection Overload 105 150 Overvoltage 57 6 64 8V Environment...

Page 14: ...Transition Networks SI IES 1200 LRT User Manual 33586 Rev D https www transition com Page 14 of 21 25130 Dimensions Dimensions Width 1 57 40 mm Depth 3 94 100 mm Height 3 54 90 mm ...

Page 15: ...IN Rail Mounting Assembling the DIN Rail Clip The DIN Rail clip is screwed on the device at the factory If not please refer to the following steps and figure to secure the DIN Rail clip on the device 1 Use the screws to secure the DIN Rail clip at the rear of the device 2 To remove the DIN Rail clip reverse step 1 ...

Page 16: ...eps below to hang the device on the standard DIN rail 1 Position the rear side of the device directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the device downward 3 Check the DIN Rail clip is tightly fixed on the DIN rail 4 To remove the device from the track reverse the steps above ...

Page 17: ...all mount plates 1 To remove the DIN Rail clip from the device unscrew the screws that secure it 2 Align the screw holes of the wall mount plates with the ones of the device 3 Use the screws included to secure the wall mount plates on the device 4 Use the hook holes of the wall mount plates to hang the device on the wall 5 To remove the wall mount plates reverse the steps above ...

Page 18: ...ED indicators which describe common problems you may encounter and where the user can find possible solutions If the power LED does not light when the power cord is plugged in you may have a problem with power cord Check for loose power connections power losses or surges at the power outlet If you still cannot resolve the problem contact your local dealer for assistance If the cables are properly ...

Page 19: ...tn RETURNS DEPT CRA RMA ___________ Failure to properly protect the product during shipping may void this warranty The return authorization number must be written on the outside of the carton to ensure its acceptance We cannot accept delivery of any equipment that is sent to us without a CRA or RMA number CRA s are valid for 60 days from the date of issuance An invoice will be generated for paymen...

Page 20: ...UCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED TRANSITION NETWORKS IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE OR THEORY AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON TRANSITION NETWORKS S BEHALF Declaration of Conformity ...