24-hour Technical Support:  

1-800-260-1312

-- International:  

00-1-952-941-7600

Cable Specifications -- Continued

CSCSCF3039-100

1300 nm multimode

Fiber-optic Transmitter Power:

min:  -19.0 dBm

max:  -14.0 dBm

Fiber-optic Receiver Sensitivity:

min:  -30.0 dBm

max:  -14.0 dBm

Link Budget:

11.0 dB

The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.

Technical Specifications

For use with Transition Networks Model SCSCF30xx-10x or equivalent

Standards

FCC Class A; EN 55022 Class A; EN 55024; ANSI
T1.102-1993; ETSI TBR-24; ITU-T G.703 G.823 for
jitter tolerance; G.775 for loss of signal; Telecordia
GR-499CORE & GR-253-CORE

Data Rate

DS3 / T3 = 44.7 Mb/s; E3 = 34.4 Mb/s

Dimensions

3.25" x 4.7" x 1.0" (83 mm x 119 mm x 25 mm)

Weight

10 oz.  (283 g) (approximately)

Power Consumption

6.0 Watts

Power Supply

12 VDC, 0.8 Amp (minimum)

DC Outlet

Minimum output regulation: 5%

MTBF (stand alone)

48,996 (MIL217F2 V5.0) (MIL-HDBD-217F)
119,854 (Bellcore7 V5.0)

Environment

Tmra*:

0 to 50°C (32° to 122°F )

Storage Temp:

-20° to 85°C (-4° to 185°F)

Humidity:

5 to 95%, non condensing

Altitude:

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature.  

For the most up-to-date information on the SCSCF30xx-10x media converter,
view the user’s guide on-line at www.transition.com.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION:  Visible and invisible laser radiation when open.  Do not stare into
beam or view directly with optical instruments.

CAUTION:  Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

9

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the PWR (Power) LED on the media converter illuminated?
NO

Ensure that the power adapter is the proper type of voltage and cycle
frequency for the outlet  (See “Power Supply” on page 8.) 

Ensure the power adapter is properly installed in the media converter
and in the grounded outlet.

Contact Tech Support:  1-800-260-1312, Int’l:  00-1-952-941-7600.

YES

Proceed to step 2.

2.

Is the SDC (Signal Detect / Coax) LED illuminated green?
NO

Check the coax cables for the proper connection.

Contact Tech Support:  1-800-260-1312, Int’l:  00-1-952-941-7600.

YES

Proceed to step 3.

3.

Is the SDF (Signal Detect / Fiber) LED illuminated green?
NO

Check the fiber cables for proper connection.

Verify that the TX and RX cables on the local media converter are
connected to the RX and TX ports, respectively, on the remote media
converter.

Contact Tech Support:  1-800-260-1312, Int’l:  00-1-952-941-7600.

YES

Proceed to step 4.

4.

Is the SDC (Signal Detect / Coax) LED flashing green?
YES 

The coax link is in loop-back mode.  For normal operation, set the
loop-back switch to the center (normal) position.

Contact Tech Support:  1-800-260-1312, Int’l:  00-1-952-941-7600.

NO 

Proceed to step 5.

5.

Is the SDF (Signal Detect / Fiber) LED flashing green?
YES 

The fiber link is in loop-back mode.  For normal operation, set the
loop-back switch to the center (normal) position.

Contact Tech Support:  1-800-260-1312, Int’l:  00-1-952-941-7600.

NO 

Proceed to step 6.

Summary of Contents for SCSCF3011-100

Page 1: ...0 75 ohm coax BNC SC 1310 mn TX 1550 nm RX 20 km 12 4 miles SCSCF3029 101 75 ohm coax BNC SC 1550 mn TX 1310 nm RX 20 km 12 4 miles SCSCF3029 100 and 101 are intended to be installed in the same netwo...

Page 2: ...use a small flatblade screwdriver or a similar device see the drawing to the right CL Coax loop back Enable loop back on the local coax interface Center Position Normal operation FL Fiber loop back E...

Page 3: ...the cover on the media converter and replace the four 4 screws that secure the cover to the media converter jumpered not jumpered J11 J12 techsupport transition com Click the Transition Now link for a...

Page 4: ...m Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB SCSCF3013 100 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivit...

Page 5: ...ents CAUTION Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure techsupport transition com Click the Transition N...

Page 6: ...Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model SCSCF30xx 10x Series Media Converter Part Number SCSCF3011 100 SCSCF3013 100 SCSCF3014 100 SCSCF3015 100 SCSCF3016 100 SCSC...

Page 7: ...ent of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le br...

Reviews: