SBFTF1010-130 

Technical Support:  1.800.466.4526. Press "2" --  International: 1.408.744.2751

Technical specifications

Standards:

IEEE 802.3

2000

Regulatory:

Emissions: EN55022 Class A, Immunity: 
EN55024 

Safety compliance:

UL listed, CE Mark 

(wall-mount power supply)

Data Rate:

10 Mbps, 100 Mbps

Dimensions:

3.25” W, 1” H, 4.8” L 

(82.6 mm x 25 mm x 121.9mm)

Weight:

10 oz. approximately  

Power consumption:

2.4 watts

Power supply: 

12VDC, 0.4A minimum

Operating temp:

0°C to 50°C 

(32°F to 140°F )

Switching time:

<189 ms 

(primary to secondary port)

Storage temp:  

-20°C to +85°C 

(-4°F to 185°F)

Humidity:

5%  to 95%, non-condensing 

Altitude:

0 – 10,000 feet

Warranty:

Lifetime

11

SBFTF1010-130 

[email protected] -- Click the “Transition Now” link for live Web chat.

Contact Us

Technical support

Technical support is available at [email protected] 

• US and Canada:  

1-800-260-1312 

(24 hours)

• International: 00-1-952-941-7600 

 

(24 hours)

Transition now

Chat live via the Web with Transition Networks Technical Support. Log onto
www.transition.com and click the Transition Now link.

Web-based seminar

Transition networks provides seminars via live, web-based training. Log onto
www.transition.com and click the Learning Center link.

Email

Ask a question anytime by sending an email to our technical support staff:
[email protected]

Address

Transition Networks

6475 City West Parkway

Minneapolis, MN  55344, U.S.A.

Telephone:  

952-941-7600, 

Toll free:  

800-526-9267

Fax:  

952-941-2322

Declaration of Conformity

Name of Mfg:

Transition Networks, 6475 City West Parkway,
Minneapolis, MN 55344 U.S.A.

Model:

SBFTF1010-130 Stand-Alone Fault-Tolerant Redundant Link
Protector

Part Number:

SBFTF1010-130 

Regulation:

EMC Directive 89/336/EEC

Purpose:

To declare that the SBFTF1010-130  to which this declaration
refers is in conformity with the following standards:

CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 Subpart B;

21CFR subpart J

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

10, 2006

Stephen Anderson, Vice-President of Engineering

Date

Summary of Contents for SBFTF1010-130

Page 1: ...gnal if the signal is present the main and primary ports connect and the signal from the backup port is then disabled Any device connected to the backup port will not detect a signal at this time Howe...

Page 2: ...able permitted by calculating the round trip delay in bit times BT of a particular collision domain If the result is less than or equal to 512 BT the path is good AutoCross When the AutoCross feature...

Page 3: ...all flatblade screwdriver or similar tool to set the DIP switch When Auto Negotiation is enabled switch 1 UP the bridging media converter advertises all rate and mode capabilities to the network 100Mb...

Page 4: ...T 100Base TX Ensure that the correct cable type is installed to support the highest speed and mode of operation Though category 3 cable is adequate for a 10Base T installation category 5 cable is rec...

Page 5: ...f the LED is ON and still no activity contact technical support 1 800 466 4526 then press 2 SBFTF1010 130 Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours 8 Cable Specifications co...

Page 6: ...Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web based seminar Transition networks provides seminars via live web based training Log onto www tra...

Page 7: ...les limites applicables aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations WA...

Reviews: