37
CPSMC18xx-xxx PointSystem
™
Chassis
24-hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model CPSMC18xx-xxx or equivalent.
Dimensions
17 x 14.3 x 3.5 inches (430 x 363 x 89 mm)
Weight
17.5 lbs. (8.0 kg)
MTBF
(Mean Time Before Failure)
MIL217F2 V5.0 (hrs)
Bellcore7 V5.0 (hrs)
CPS CPSMP-200
82,539
223,289
CPS CPSMP-200 + CPSMM-200
52,564
170,073
CPS CPSMP-210
166,283
385,512
CPS CPSMP-210 + CPSMM-200
77,383
250,295
CPSMP-200
Power Input:
100-240 V, 50/60 Hz, 0.62-1.5 Amp (typical with a fully-loaded chassis)
Power Output:
+12 VDC at 10.83 Amp maximum.
CPSMP-210
Power Input:
48-VDC (38 to 58 VDC) @ 4.0 Amp (typical with a fully-loaded chassis)
Power Output:
+12 VDC at 12.5 Amp maximum.
Environment
Tmra*:
0 to 50°C (32 to 122°F) (*Manufacturer’s rated ambient temperature)
0 to 60°C (32 to 140°F) (when redundant power or fan module is used)
Storage Temperature:
-40 to 80°C (-40 to 176°F)
Humidity
5 to 95%, non condensing
Altitude
0 to 10,000 feet
Compliance
EN 55022:1998+A1:2000 Class A & B; EN 55024:1998; UL Listed;
FCC Part 15 Subpart B; CE Mark; 21 CFR Subpart J
Warranty
Lifetime
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date
of manufacture.
The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC-825/CDRH standards
and complies with 21 CFR1040.10 and 21CFR1040.11.
CAUTION:
Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or View Directly
With Optical Instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other than those specified herein