Grounding the media converter
The single-slot chassis comes equipped with grounding lugs located on the back
panel. They require a grounding conductor wire terminated with a two-hole,
compression-type grounding connector. The grounding wire—which must be a
copper conductor—is not included with the chassis and must be provided by the
customer/installer.
The electrical conducting path from the single-slot chassis must do the following:
• Flow via the grounding lugs to the common bonding network (CBN) for telecom
installations, or to an alternative approved grounding system
(if required)
for
non-telecom installations
• Be of sufficiently low impedance to conduct fault currents likely to be imposed
on the media converter
• Enable proper operation of any over-current protection devices
The conductor must be fastened to the grounding lugs with the enclosed anti-
rotation star-washers and lug-nut fasteners. The applied torque required to the
connector lug-nut fasteners is specified by the connector’s manufacturer.
To properly ground the single-slot chassis:
1. Obtain one (1) grounding conductor
(12 AWG copper wire or larger)
with a two-
hole, compression-type grounding connector.
2. Attach the grounding conductor to the converter by placing the two-hole
connector onto the grounding lugs and fasten with the enclosed lock-washers /
lug-nuts at the proper torque
(per the manufacturer’s specification)
.
3. Attach the opposite end of the
grounding conductor to the
common bonding network (CBN)
for telecom, or to earth ground
(if
required)
for non-telecom
installations.
Grounding Lugs
Connect to E arth Ground
¾"
Grounding S crew
6-32 x 1/8"
St ar Was her
Lug Nut
12 AWG Copper Wire
(not included)
[email protected] -- Click the “Transition Now” link for a live Web chat.
5
Technical Specifications
For use with Transition Networks Model CPSMC0100-226 or equivalent.
Note:
The CPSMC0100-226 single-slot chassis is Class B compliant ONLY if Class
B compliant media converters are installed. Installation of a Class A compliant
media converter reduces the chassis to Class A compliance.
Compliance
EN55022; Class A&B; CE Mark
Dimensions
3.875 x 5.5 x 1.0 in
(98 x 140 x 25 mm)
Weight 16
oz.
(454 g)
approximately
MTBF*: 394,241
hours
(MIL217F2 V5.0) (MIL-HDBK-217F)
233,811,224 hours
(Bellcore7 V5.0)
Maximum power delivery capacity
CPSMC0100-226:
6 Watts
Power supplies:
Shipped: 12VDC, 1.25A, 100-240VAC, 50/60Hz
Optional: 12VDC, 2.5A, 100-240VAC, 50/60Hz
Environment
Tmra**:
0 to 60°C
(32 to 140° F )
Storage Temp:
-40 to 85°C
(-40 to 185°F)
Humidity:
5 to 95%, non-condensing
Altitude:
0 to 10,000 feet
Warranty:
Lifetime
The information in this user’s guide is subject to change. For the most up-to-date
information on the CPSMC0100-226 single-slot chassis, view the user’s guide on-line
at: www.transition.com.
WARNING: Visible and invisible laser radiation when open. Do not stare into the
beam or view the beam directly with optical instruments. Failure to observe this
warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
*MTBF is estimated using the predictability method. This method is based on MIL-
217F at 25°C ambient temperature, typical enclosure heat rise of 10°C, and nominal
operating conditions and parameters. Installation and configuration specific MTBF
estimates are available upon request. Contact Technical Support.
**Manufacturer’s rated ambient temperature is for the single-slot chassis. Refer to the