background image

Transition Networks, Inc. 

 

 

 

 

 

M/GE-PSW-xX-01 User Guide 

33398 Rev. D 

https://www.transition.com/ 

Page 3 of 15 

Applications  

Connect legacy networking equipment: connect an existing 10/100 Mbps device to 1000 Mbps devices. 

 

Package Contents 

Make sure you have received the items below. Contact your sales representative if any items are 
missing. Save the packaging for possible future use.  

 

One M/GE-PSW-SX-01 

 

One Power Supply  

 

One Documentation postcard 

 

M/GE-PSW-SX-01

 

 

Summary of Contents for M/GE-PSW-LX-01

Page 1: ...and Fiber Ports 4 Connect the Fiber Cable 4 Connect the Twisted pair Copper Cable 5 Power up the Media Converter 5 Operation 6 Status LEDs 6 Features 6 Cable Specifications 9 Technical Specifications...

Page 2: ...100 1000Base T RJ 45 100 m 328 ft to 1000Base SX 850nm multimode LC 62 5 125 m fiber 220 m 722 ft Link Budget 7 0 dB 50 125 m fiber 550m 1804 ft Link Budget 7 0 dB M GE PSW LX 01 10 100 1000Base T RJ...

Page 3: ...cy networking equipment connect an existing 10 100 Mbps device to 1000 Mbps devices Package Contents Make sure you have received the items below Contact your sales representative if any items are miss...

Page 4: ...media converter Connect the Fiber Cable Full duplex always ON is on the fiber side only therefore the 512 Bit Rule does not apply The cable lengths are constrained by the cable requirement 1 Locate or...

Page 5: ...anently enabled the link LED only lights when a valid end to end connection is made Power up the Media Converter The M GE PSW SX 01 media converter is powered by using a DC power adapter through the b...

Page 6: ...ter filters packets destined for local devices which reduces network congestion Auto Negotiation The Auto Negotiation feature is ON permanently for the M GE PSW xX 01 media converters Auto Negotiation...

Page 7: ...up of the converter Upon removing the converter s SFP module if equipped In the Diagnostic state the link for each of the media converter s ports can come up independently of each other just like a c...

Page 8: ...al switch or router The 512 Bit Rule determines the maximum length of cable permitted by calculating the round trip delay in bit times BT of a particular collision domain If the result is less than or...

Page 9: ...ceiver Sensitivity min 17 0 dBm max 0 0 dBm Link Budget 7 0 dB M GE PSW LX 01 1310 nm single mode Fiber optic Transmitter Power min 9 5 dBm max 3 0 dBm Fiber optic Receiver Sensitivity min 20 0 dBm ma...

Page 10: ...m Cable Distance 100 meters Straight through or crossover twisted pair cable may be used Shielded STP or unshielded UTP twisted pair cable may be used Pins 1 2 and 3 6 are the two active pairs in an E...

Page 11: ...od is based on MIL 217F at 25 C ambient temperature typical enclosure heat rise of 10 C with nominal operating conditions and parameters Installation and configuration specific MTBF estimates are avai...

Page 12: ...tep 2 Note As a link pass through device both the copper and the fiber cables must be installed before the LEDs will light 2 Are the FX Link and TX Link Act LEDs lit on the RJ 45 port NO Check the cop...

Page 13: ...x 952 941 2322 sales transition com techsupport transition com customerservice transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A Web https www transition com...

Page 14: ...ada European regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung...

Page 15: ...nge format add ALPT feature at FW Rev C and update contact information D 6 4 21 Add M GE PSW SX 01 LC and add PEM to top metals Trademark Notice All trademarks and registered trademarks are the proper...

Reviews: