Transition Networks M/E-PSW-FX-01 User Manual Download Page 3

4

Mx/E-PSW-FX-01

Tech Support: 1-800-260-1312  International: 00-1-952-941-7600 

(24 hours)

Installation 

-- Continued

Connect the twisted-pair copper cable 

The AutoCross feature allows either MDI 

(straight-through)

or MDI-X 

(crossover)

cable connections to be configured automatically, according to network conditions.

If half-duplex mode is used, refer to the 512-Bit Rule. 

If full-duplex mode is used, the 512-Bit Rule does not apply.  The cable
lengths are constrained by the cable requirements. 

1.

Locate or build IEEE 803.2™ compliant 10Base-T or 100Base-TX  cables,
with RJ-45 connectors installed at both ends.

2.

Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the
Mx/E-PSW-FX-01 media converter.

3.

Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on
the other device 

(switch, workstation, etc.).

RJ-45 port

on the other device

(switch, work station, etc.)

RJ-45 port

on the media 

converter

Power warnings

WARNING:  If the media converter is an IEEE802.3-2005 Powered Device (PD)
capable of receiving power via the Media Dependent Interface (MDI) leads, the
power source, connector, and cables attached to the barrel power connector must
meet the isolation requirement specified in IEEE802.3-2005. 

WARNING: When powering the model MP/E-PSW-FX-01 via “Power over
Ethernet” only, a barrel cover 

(provided)

must be installed on the back panel of the

converter for safety. Failure to observe this warning could result in an electrical
shock. 

[email protected] -- Click the “Transition Now” link for a live Web chat.

5

Installation -- Continued

Powering the media converter

The power options for the Mx/E-PSW-FX-01 media converter are product dependent.
The following shows the various power configurations associated with each model. 

Barrel Connector
5 - 50VDC

US B

Power

Back P anel

MU/E -PS W-F X-01

MP /E- PSW- F X-01

Ba ck Pa nel

Barrel Connector
5 - 50VDC

F ront P anel

Power Over

Et hernet

M/E-PSW-FX-01 Back Panel Power 

MU/E-PSW-FX-01 Back Panel Power Options 

Barrel Cover Cutout

Ba ck Pa nel

Barrel Uncovered

Ba rrel Cover

MP/E-PSW-FX-01 Back-Panel Barrel Safety Cover 

(only on this model)

MP/E-PSW-FX-01 Back Panel Power Options 

Back Pa nel

M/E-PS W-FX-01

Barrel Connector
5 - 50VDC

Summary of Contents for M/E-PSW-FX-01

Page 1: ...ion 15 Part Number Copper Port 10Base T 100Base TX Fiber Optic Port 100Base FX M E PSW FX 01 ST RJ 45 100 m 328 ft ST 1300 nm multimode 2 km 1 2 miles M E PSW FX 01 SC RJ 45 100 m 328 ft SC 1300 nm mu...

Page 2: ...ng strap before handling any module or component If you do not have a wrist strap maintain grounded contact with the system unit throughout any procedure requiring ESD protection Single Strand Fiber M...

Page 3: ...ed Device PD capable of receiving power via the Media Dependent Interface MDI leads the power source connector and cables attached to the barrel power connector must meet the isolation requirement spe...

Page 4: ...e best possible mode of operation over a link It broadcasts speed 10 Mb s or 100 Mb s and duplex capabilities full or half to the other device and negotiates the best mode of operation Auto Negotiatio...

Page 5: ...Media Converter Auto Negotiation AutoCross LPT FEF M E PSW FX 01 Yes Yes No Yes MP E PSW FX 01 Yes Yes Yes Yes MU E PSW FX 01 Yes Yes Yes Yes Auto Negotiation AutoCross Link Pass Through Far End Fault...

Page 6: ...ode Fiber optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB MU E PSW FX 01 SM 1310 nm single mode Fiber optic Transmitter...

Page 7: ...n damage to equipment techsupport transition com Click the Transition Now link for a live Web chat 13 Troubleshooting If the media converter fails isolate and correct the failure by determining the an...

Page 8: ...ion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations T...

Page 9: ...the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der...

Reviews: