LANMaster™ T8

8-Port Ethernet™ Repeater Hub

20

CAUTION:  RJ connectors are NOT INTENDED FOR
CONNECTION TO THE PUBLIC TELEPHONE
NETWORK. Failure to observe this caution could result
in damage to the public telephone network.

Compliance Information
UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class
A digital device, pursuant to part 15 of the FCC rules.  These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.  This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user
will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for
digital apparatus set out on the radio interference regulations of the Canadian
Department of Communications.

European Regulations
Warning

This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.

Copyright Restrictions

©  1997 TRANSITION Networks.
All rights reserved.  No part of this work may be reproduced or used in any
form or by any means – graphic, electronic, or mechanical – without written
permission from TRANSITION Networks.

Trademark Notice

All registered trademarks and trademarks are the property of their respective
owners.

Der Anschluss dieses Gerätes an ein öffentlickes
Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die
jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie
91/263/EWG zur Angleichung der Rechtsvorschriften der
Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

10BASE-2 Cable Specifications

The physical characteristics of the 10BASE-2 cable must meet or exceed IEEE 802.3
10BASE-2 specifications. 

Cable Characteristics: 

Cable type:

Stranded Coaxial RG58 (ThinNet)

Impedance: 50 

@ 10 MHz 

Mutual Capacitance:

24 pF/ft ±20% @ 10 MHz

Maximum Cable Length

:

185 meters (610 feet)

Maximum number network connections:

30

Minimum distance between connections:

0.5 meters (1.6 feet)

Terminate 10BASE-2 cable at one end using a 50 ohm terminator and at the

other end using a 50 ohm terminator grounded to earth ground.

10BASE-T Cable and Connector Specifications

The physical characteristics of the 10BASE-T cable must meet or exceed IEEE
802.3 10BASE-T specifications. 

10BASE-T Cable Characteristics: 

Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.

Category 3:

Gauge

24 to 22 AWG

Attenuation 

28 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Category 5:

Gauge

24 to 22 AWG

Attenuation 

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Maximum Cable Length:

100 meters (330 feet)

10BASE-T Connector Characteristics:

The two active pairs  in a 10BASE-T network are pins 1 & 2 and pins 3 & 6.
Use only dedicated wire pairs (such as blue/white & white/blue, orange/white
& white/orange) for the active pins. 10BASE-T cable for unlike devices (such as
hub to terminal device) must be configured as straight through; 10BASE-T
cable for like devices (such as hub to hub or terminal device to terminal
device) must be configured as crossover.

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Connectors for like devices

1

2

3

6

1

2

3

6

1

2

3

6

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Connectors for unlike devices

1

2

3

6

Summary of Contents for LAN MASTER 33022.B

Page 1: ...NS Standards IEEE 802 3 Physical Dimensions 137 mm x 137 mm x 25 mm Power Power Supply Adapter AC Input 47 63 hertz PN Requirement Location 3532 120 volts 60 hertz 28 watts USA Canada Mexico 3535 230 volts 50 hertz 28 watts Europe 3534 100 volts 50 60 hertz 28 watts Japan 3533 240 volts 50 hertz 28 watts United Kingdom 3536 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 800 mA maximum...

Page 2: ...igen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10BASE 2 Cable Specifications The physical characteristics of the 10BASE 2 cable must meet or exceed IEEE 802 3 10BASE 2 specifications Cable Characteristics Cable ty...

Page 3: ...c Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10BaseFL Cable Characteristics Fiber Optic Cable Recommended 62 5 125 µm multimode fiber Optional 100 140 µm multimod...

Page 4: ...from all causes in the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of d...

Page 5: ...ANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDI...

Page 6: ...nal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two network devices fail to communicate through the LANMaster T8 consider the following Are the LEDs described in the previous section functioning properly Do network devices have Link Integrity enabled Do network devices communicate when the LANMaster T8 is not...

Page 7: ... must provide AC power outlet for each LANMaster T8 Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone lines should be separated from data cable...

Page 8: ...oltage AC wall socket 5 At LANMaster T8 front verify that Act ivity LED is illuminated 3 INSTALLATION To install the LANMaster T8 Unpack the LANMaster T8 Install LANMaster T8 at site Install Network Cable Power the LANMaster T8 Direction is provided in the pages that follow Unpacking the LANMaster T8 The LANMaster T8 packing contents should include the following Item Part Number LANMaster T8 Hub E...

Page 9: ...nting bracket so that mounting screws are secured at narrow end of bracket mounting 2 1 2 X 1 2 3 4 5 6 7 8 3 Installing Thicknet 10BASE 5 Cable The LANMaster T8 provides a female AUI connector at the back for network connection to 10BASE 5 through an AUI drop cable or to 10BASE 2 10BASE T or 10BASE FL through a transceiver CONNECTING TO 10BASE 5 USING AUI DROP CABLE To connect to 10BASE 5 cable u...

Page 10: ...to 10BASE 2 cable and comes with a mating T connector and a 50 ohm segment terminator for making the cable connection To connect to 10BASE 2 network cable 1 Locate or build IEEE 802 3 compliant 10BASE 2 cable with male BNC connectors installed at both ends 2 Install the mating T connector to the female BNC connector on the LANMaster T8 3 Install 10BASE 2 cable to one side of the T connector 4 Inst...

Page 11: ... 5 cable by monitoring the shield voltage level more than one ground could cause false collisions that result in repeater ports partitioning and network traffic beyond the partition ceasing 10BASE 2 Requirements Thinnet 10BASE 2 cable daisy chains network devices With a maximum segment length of 185 meters and a minimum segment length of 0 5 meters the coaxial cable must have a 50 ohm characterist...

Page 12: ...n repeaters or between repeaters and network devices To verify the network configuration by assigning segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the terminals segment 1 and the segment connected to the other terminal s...

Reviews: