4
F-SM-MM-06
Tech Support:
800-260-1312
International:
952-941-7600
7am-6pm CST (GMT-6:00)
CABLE SPECIFICATIONS
The physical characteristics must meet or exceed ANSI TI.646-1995, ITU G.957
specifications.
Bit Error Rate:
<10-10
Multimode
1300 nm
Recommended:
62.5/125 µm
Optional:
100/140, 85/125, 50/125 µm
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -26.0 dBm
max: -14.0 dBm
Link Budget:
7.0 dB
Minimum cable distance*
2 meters (6.6 ft)
Typical maximum cable distance*
2 km (1.2 miles)
Singlemode
Recommended:
9 µm
F-SM-MM-06
1310 nm
Fiber Optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber Optic Receiver Sensitivity:
min: -28.0 dBm
max: -7.0 dBm
Link Budget:
13.0 dB
Minimum cable distance*
2 meters (6.6 ft)
Typical maximum cable distance*
15 km (9.3 miles)
F-SM-MM-06(XL)
1310 nm
Fiber Optic Transmitter Power:
min: -3.0 dBm
max: +2.0 dBm
Fiber Optic Receiver Sensitivity:
min: -29.0 dBm
max: -7.0 dBm
Link Budget:
26.0 dB
Minimum cable distance*
2 meters (6.6 ft)
Typical maximum cable distance*
40 km (24.9 miles)
* Actual distance is dependent upon the characteristics of the network
installation.
5
-- Select the
“Transition Now”
Link for a Live Web Chat
TECHNICAL SPECIFICATIONS
For use with Transition Networks Model F-SM-MM-06 or equivalent
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
Standards:
ANSI TI.646-1995, ITU G.957
Data Rate:
622 Mb/s
Case Dimensions:
4.7" x 3.0" x 1.0" (119 mm x 76 mm x 25 mm)
Weight:
10 oz. (283 g) (approximate)
Power Consumption:
3.1 W
Power Supply
12VDC, 0.4 A (minimum)
DC Output:
minimum output regulation: 5%
Connector: 2.1mm barrel, center pin positive
MTBF
51,185 hours
(MIL217F2 V5.0) (MIL-HDBK-217F)
124,339 hours
(Bellcore7 V5.0)
Environment:
Tmra*:
0 to 50°C (32 to 122°F)
Storage Temp:
-20 to 85°C (-4 to 185°F)
Humidity:
10 to 90%, non condensing
Altitude:
0 to 10,000 feet
Warranty:
Lifetime
*Manufacturer’s rated ambient temperature.
CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare
Into Beam Or View Directly With Optical Instruments.
CAUTION: Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.