background image

F-SM-MM-06

Tech Support: 

800-260-1312

International: 

952-941-7600

7am-6pm CST (GMT-6:00)

CABLE SPECIFICATIONS

The physical characteristics must meet or exceed ANSI TI.646-1995, ITU G.957
specifications. 

Bit Error Rate:  

<10-10

Multimode 

1300 nm

Recommended:

62.5/125 µm 

Optional:  

100/140, 85/125, 50/125 µm  

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -26.0 dBm

max: -14.0 dBm

Link Budget:

7.0 dB

Minimum cable distance*

2 meters (6.6 ft)

Typical maximum cable distance*

2 km (1.2 miles)

Singlemode

Recommended:

9 µm 

F-SM-MM-06

1310 nm 

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber Optic Receiver Sensitivity:

min: -28.0 dBm

max: -7.0 dBm

Link Budget:

13.0 dB

Minimum cable distance*

2 meters (6.6 ft)

Typical maximum cable distance*

15 km (9.3 miles)

F-SM-MM-06(XL)

1310 nm 

Fiber Optic Transmitter Power:

min: -3.0 dBm

max: +2.0 dBm

Fiber Optic Receiver Sensitivity:

min: -29.0 dBm

max: -7.0 dBm

Link Budget:

26.0 dB

Minimum cable distance*

2 meters (6.6 ft)

Typical maximum cable distance*

40 km (24.9 miles)

*  Actual distance is dependent upon the characteristics of the network
installation.

[email protected]

-- Select the 

“Transition Now”

Link for a Live Web Chat

TECHNICAL SPECIFICATIONS

For use with Transition Networks Model F-SM-MM-06 or equivalent

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

Standards:

ANSI TI.646-1995, ITU G.957 

Data Rate:

622 Mb/s

Case Dimensions:

4.7" x 3.0" x 1.0" (119 mm x 76 mm x 25 mm)

Weight:

10 oz. (283 g) (approximate)

Power Consumption:

3.1 W

Power Supply 

12VDC, 0.4 A (minimum)

DC Output:

minimum output regulation: 5%
Connector: 2.1mm barrel, center pin positive

MTBF

51,185 hours 

(MIL217F2 V5.0) (MIL-HDBK-217F)

124,339 hours 

(Bellcore7 V5.0)

Environment:

Tmra*:

0 to 50°C (32 to 122°F)

Storage Temp:

-20 to 85°C (-4 to 185°F)

Humidity:

10 to 90%, non condensing 

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

*Manufacturer’s rated ambient temperature. 

CAUTION:  Visible and Invisible Laser Radiation When Open.  Do Not Stare
Into Beam Or View Directly With Optical Instruments.

CAUTION:  Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.

Summary of Contents for F-SM-MM-06(XL)

Page 1: ...more information on the cable length Optional Accessories sold separately Installation 2 Operation 3 Cable Specifications 4 Technical Specifications 5 Fault Isolation and Correction 6 Contact Us 7 Compliance Information 8 Part Number Description SPS 1872 SA Optional External Power Supply 18 72VDC Stand Alone Output 12 6VDC 1 0 A SPS 1872 CC Optional External Power Supply 18 72VDC Piggy back Output...

Page 2: ...ct the fiber cable to the other device media converter hub etc as shown RX TX RX TX Power the Media Converter AC 1 Install the power adapter cord to the back of the Media Converter 2 Connect the power adapter plug to AC power 3 Verify that the Media Converter is powered by observing the illuminated LED power indicator light DC Consult the User s Guide for the Transition Networks SPS1872 xx DC Exte...

Page 3: ... 40 km 24 9 miles Actual distance is dependent upon the characteristics of the network installation 5 techsupport transition com Select the Transition Now Link for a Live Web Chat TECHNICAL SPECIFICATIONS For use with Transition Networks Model F SM MM 06 or equivalent Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture Standar...

Page 4: ...Canada 1 800 260 1312 International 00 1 952 941 7600 DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model F SM MM 06 Series Media Converters Part Number s F SM MM 06 F SM MM 06 XL Regulation EMC Directive 89 336 EEC Purpose To declare that the F SM MM 06 to which this declaration refers is in conformity with the following standards EMC CI...

Page 5: ...s de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate mea...

Reviews: