Transition Networks E-TBT-HB-1600 Manual Download Page 9

LANMaster™ T16

16-Port Ethernet™ Repeater Hub

6

13

Installing LANMaster T16 at Site

NOTE: Rackmount brackets, screws, and rubber feet are provided.

To install the LANMaster T16 in 19-inch rack cabinet:

1. Install right and left front brackets on LANMaster T16 by

installing three (3) screws through each bracket into
LANMaster T16 chassis.

2. Carefully align the LANMaster T16 between the 19-inch rack

mounting rails.

3. Install LANMaster T16 by installing two (2) screws through

right front bracket and two screws through left front bracket,
using clip nuts to secure if necessary.

To install the LANMaster T16 on table or other flat surface:

1. Carefully turn LANMaster T16 to side.

2. Install four (4) rubber feet included with packing material:

Separate rubber feet.

Remove protective paper from adhesive surface on each
rubber foot.

Position and secure each rubber foot as shown.

3. Return LANMaster T16 to upright position.

Installing Thicknet 10BASE-5 Cable

The LANMaster T16 provides a female AUI connector at the back for
network connection to 10BASE-5 through an AUI drop cable or to
10BASE-2, 10BASE-T, or 10BASE-FL through a transceiver. 

CONNECTING TO 10BASE-5 USING AUI DROP CABLE

To connect to 10BASE-5 cable using AUI drop cable:

1. Locate or build IEEE 802.3 compliant AUI drop cable.

2. Connect AUI drop cable

male connector to female
AUI (DTE) connector on
LANMaster T16.

3. Connect AUI drop cable

female connector to the AUI
port on a 10BASE-5 cable
transceiver or media
attachment unit (MAU).

4. Verify that 10BASE-5

segment is terminated at both ends using 50-ohm terminators.

CONNECTING TO NETWORK USING TRANSCEIVER

NOTE: Refer to transceiver documentation for detailed specifications.

To connect to network using transceiver:

1. Locate IEEE 802.3 compliant transceiver with male AUI

connector and with required network media connector.

2. Connect transceiver male AUI connector to the female AUI

connector on LANMaster T16.

3. Referring to transceiver documentation, connect transceiver

network media connector to the network media.

50 ohm terminator

TO FIBER, COAX,
OR TWISTED PAIR

Summary of Contents for E-TBT-HB-1600

Page 1: ...ICATIONS Standards IEEE 802 3 Physical Dimensions 431 mm x 162 mm x 45 mm Input Power Universal Power Supply Input Range 90 to 265 VAC at 47 to 63 Hz AC Input TN PN Requirement Location 3344 120 volts...

Page 2: ...sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliessl...

Page 3: ...11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical cha...

Page 4: ...aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to...

Page 5: ...NC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS...

Page 6: ...6 Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two net...

Page 7: ...n of valid data 2 SITE CONSIDERATIONS The site for the LANMaster T16 must provide AC power outlet for each LANMaster T16 Adequate ventilation Standard environmental conditions Isolation from electrica...

Page 8: ...lay fuse Carefully remove fuse from fuse holder Install same size and rating replacement fuse in fuse holder Return fuse holder and fuse to installation position Snap fuse holder into place Connect po...

Page 9: ...SE 5 Cable The LANMaster T16 provides a female AUI connector at the back for network connection to 10BASE 5 through an AUI drop cable or to 10BASE 2 10BASE T or 10BASE FL through a transceiver CONNECT...

Page 10: ...2 cable and comes with a mating T connector and a 50 ohm segment terminator for making the cable connection To connect to 10BASE 2 network cable 1 Locate or build IEEE 802 3 compliant 10BASE 2 cable...

Page 11: ...level more than one ground could cause false collisions that result in repeater ports partitioning and network traffic beyond the partition ceasing 10BASE 2 Requirements Thinnet 10BASE 2 cable daisy...

Page 12: ...independent network cable connection between repeaters or between repeaters and network devices To verify the network configuration by assigning segment numbers to cable connections 1 Determine the t...