LANMaster™ T16

16-Port Ethernet™ Hub

LANMASTER T16 16-PORT HUB

SPECIFICATIONS

Standards

IEEE 802.3

Physical

Dimensions

431 mm x 162 mm x 45 mm

Input Power

Universal Power Supply

Input Range:

90 to 265 VAC at 47 to 63 Hz.

AC Input: 

TN PN Requirement

Location

3344

120 volts, 60 hertz

USA/Canada/Mexico

3344

100 volts, 50-60 hertz

Japan

3347

230 volts, 50 hertz

Europe

3348

240 volts, 50 hertz

Australia

3349

240 volts, 50 hertz

United Kingdom

3522

230 volts, 50 hertz

South Africa

Environment

Temperature:

0-50°C (32° to 122° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Warranty

5 years

21

Summary of Contents for E-TBT-HB-1600

Page 1: ...ICATIONS Standards IEEE 802 3 Physical Dimensions 431 mm x 162 mm x 45 mm Input Power Universal Power Supply Input Range 90 to 265 VAC at 47 to 63 Hz AC Input TN PN Requirement Location 3344 120 volts...

Page 2: ...sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliessl...

Page 3: ...11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical cha...

Page 4: ...aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to...

Page 5: ...NC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS...

Page 6: ...6 Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two net...

Page 7: ...n of valid data 2 SITE CONSIDERATIONS The site for the LANMaster T16 must provide AC power outlet for each LANMaster T16 Adequate ventilation Standard environmental conditions Isolation from electrica...

Page 8: ...lay fuse Carefully remove fuse from fuse holder Install same size and rating replacement fuse in fuse holder Return fuse holder and fuse to installation position Snap fuse holder into place Connect po...

Page 9: ...SE 5 Cable The LANMaster T16 provides a female AUI connector at the back for network connection to 10BASE 5 through an AUI drop cable or to 10BASE 2 10BASE T or 10BASE FL through a transceiver CONNECT...

Page 10: ...2 cable and comes with a mating T connector and a 50 ohm segment terminator for making the cable connection To connect to 10BASE 2 network cable 1 Locate or build IEEE 802 3 compliant 10BASE 2 cable...

Page 11: ...level more than one ground could cause false collisions that result in repeater ports partitioning and network traffic beyond the partition ceasing 10BASE 2 Requirements Thinnet 10BASE 2 cable daisy...

Page 12: ...independent network cable connection between repeaters or between repeaters and network devices To verify the network configuration by assigning segment numbers to cable connections 1 Determine the t...

Reviews: