Maintenance
Replace the Fuse
1.
Set the On/Off switch to “0”.
2.
Remove the power cord from the AC wall socket.
3.
Insert a small flat blade screwdriver into the groove on the front inside
edge of the fuse holder and carefully pry the fuse holder from the power
supply module.
4.
Carefully remove the fuse from the fuse holder.
5.
Install the same size and rating replacement fuse into the fuse holder.
6.
Return the fuse holder and fuse to the installation position in the power
supply module and snap the fuse holder into place.
7.
Connect the power cord to the external AC outlet.
8.
Set the ON/OFF switch to “I”.
NOTE:
The power LED indicators on the front of the installed media
converters will illuminate when installation is complete.
I
O
1
fuse holder
fuse
-- Click the
“Transition Now”
link for a live Web chat.
7
Declaration of Conformity
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
Model:
E-MCR-04 Media Converter
Part Number:
E-MCR-04,
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the
E-MCR-04 to which this declaration refers is in
conformity with the following standards.
EN 55022:1998 A1:2000 Class A; EN 55024:1998; FCC Part 15 Subpart B; UL 1950,
EN 61000-3-2:1995+A14:2000; EN61000-3-3:1995
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
July, 2007
Stephen Anderson, Vice-President of Engineering
Date
Technical Specifications
For use with Transition Networks Model E-MCR-04 or equivalent.
Standards:
UL listed, FCC & CISPR Class A; CE Mark
Dimensions:
17.0" x 15.0" x 5.0"
(432 mm x 381 mm x 127 mm)
Weight:
8 lbs.
(3.6 kg) (approximately)
Power Requirements:
Ensure that the available power circuits are not
overloaded and that the media converter rack is
reliably grounded.
Input Voltage:
85 to 264 VAC
Input Frequency:
47 to 63 Hz
Output Voltage:
12 VDC
Output Current:
600 mA per port maximum
Environment:
Tmra*
0 to 50°C
(32 to 122°F)
Storage Temp:
-25 to 85°C
(-13 to 185°F)
Humidity:
10 to 90%, non condensing
Altitude:
0 to 10,000 feet
Warranty:
Lifetime
*Manufacturer’s rated ambient temperature.
Compliance Information
UL Listed, C-UL Listed
(Canada)
, CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.