Transition Networks E-FRL-MC04 User Manual Download Page 3

CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications. 

Fiber-Optic Interface

850nm M

ULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

Average:

-15 dBm

Fiber Optic Receiver Sensitivity:

Average :

-33 dBm

Bit error rate:

10-10

Maximum Cable Distance:

2 kilometers (6,600 feet)

1300nm M

ULTIMODE

F

iber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

Average:

-17 dBm

Fiber Optic Receiver Sensitivity:

Average:

-35 dBm

Bit error rate:

10-9

Maximum Cable Distance:

5 kilometers (16,500 feet)

1300nm SINGLEMODE

Fiber Optic Cable Recommended:

9/125 micron single mode fiber

Fiber Optic Transmitter Power:

Average:

-16 dBm

Fiber Optic Receiver Sensitivity:

Average:

-33 dBm

Bit error rate:

10-10

Maximum Cable Distance:

20 kilometers (66,000 feet)

AUI (DB-15) Interface 

Parameter

Minimum

Typical

Maximum

Transmit
Transmit threshold voltage level:

-140mV

-170mV

-190mV

Transmit turn on delay:

100ns

Transmit steady propagation delay:

15ns

50ns

Transmit loop back start up delay:

500ns

Transmit turn off to data idle:

400ns

2100ns

SQE test delay:

0.6 µ sec

1.6 µ sec

SQE test duration:

0.5 µ sec

1.0 µ sec

1.5 µ sec

Receive
Receive turn on delay:

350ns

Receive steady propagation delay:

15ns

50ns

Differential output voltage (RX(-/+)):

(+/-)550mV

(+/-)1200

Differential output voltage (col(-/+)):

(+/-)550mV

(+-)1200

Differential output rise time (RX(-/+), col(-/+)): 4ns
Differential output fall time (RX(-/+), col(-/+)):

4ns

Collision
Time for SQE to deact. after collision:

450ns

700ns

Collision frequency:

8.5MHz

11.5MHz

Collision pulse duty cycle:

40%

50%

60%

SQE test delay:

0.6 µ sec

1.6 µ sec

Jabber activation delay:

20ms

70ms

150ms

INSTALLATION 

Set Switches

Two (2) switches are located on the top of the transceiver.

SQE Off/SQE On: Selects SQE test function.  Set

to SQE On when connecting to IEEE 802.3
compliant repeaters.  Set to SQE Off when
connecting to other devices. 

HDX/FDX: Selects either half-duplex (HDX) or full-duplex (FDX) data

transmission. Set according to network installation.

Install Cable

NOTE: See page 6 for cable specifications. 

1.

Locate or build 10BASE-FL compliant cables with male two-
stranded TX to RX connectors at both ends.

2.

Connect male TX and RX cable connectors at one end of cable to
TX and RX female connectors, respectively, on transceiver.

3.

Connect male TX and RX cable connectors at other end of cable
to RX and TX connectors of 802.3 compliant fiber device..

Connect to Power

The E-FRL-MC04 is powered through the AUI connection.

er

SQE Off

SQE On

FDX

HDX