MDI switch setting

MDI-X switch setting

100 meters

100 meters

2 kilometers - multimode
20 kilometers - singlemode

Straight Through/Crossover Cable Requirements and Pin Specifications

The two active pairs in a
100BASE-TX network are pins
1 & 2 and pins 3 & 6. Use only
dedicated wire pairs (such as
blue/white & white/blue,
orange/white & white/orange)
for the active pins.

1

2

3

6

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

1

2

3

6

Straight-through/crossover 100BASE-TX requirements are satisfied
using the MDI/MDI-X switch with straight-through cable.

100BASE-TX cable connections between a hub and the media
converter require the MDI/MDI-X switch to be set to MDI. 

100BASE-TX cable connections between the media converter and a
terminal, transceiver or NIC require the switch to be set to MDI-X.

Using small flatblade
screwdriver or similar
tool and referring to
label at front of media
converter, set
MDI/MDI-X switch
position for site
installation.

100BASE-TX Cable

1. Is the power LED on the media converter illuminated?

NO

Is the power adapter the proper type of voltage and cycle frequency for your AC outlet?
NOTE: Refer to the  “Power Supply Requirements” on the back page. 

Is the power adapter properly installed in the media converter and in the outlet?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2. Is the 100BASE-TX Link LED illuminated?

NO

Check UTP cables for proper connection and pin assignment.  (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3. Is the fiber Link LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other 100BASE-FX device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

Troubleshooting the Media Converter 

Installation Notes

The physical characteristics of the media cable must meet or exceed IEEE
802.3u 100BASE-TX and 100BASE-FX specifications. 

ETHERNET CABLE SPECIFICATIONS

100BASE-FX CABLE SPECIFICATIONS

SINGLEMODE
Fiber-optic Cable Recommended:

9 µm singlemode fiber

Fiber-optic Transmitter Power:

min: -15.0 

dBm

max: -8.0 

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -8.0 

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

20 kilometers

MULTIMODE
Fiber-optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber-optic Transmitter Power:

min: -19.0 

dBm

max: -14.0 

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 

dBm

max: -14.0 

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

2 kilometers

100BASE-TX CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted pair
(STP) or unshielded twisted pair (UTP) can be used. DO NOT USE
FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation 

20 dB/1000’ @ 10 MHz

Impedance 100 

±10% @ 10 MHz 

Maximum Cable Distance:

100 meters (330 feet)

DO NOT CONNECT MEDIA CONVERTERS BETWEEN HUBS

When connecting to 10Mb/s-100Mb/s device, MANUALLY SET 10Mb/s-100Mb/s SWITCH to 100Mb/s.

KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE

Be certain that the 100BASE-TX MDI/MDI-X switch is set correctly for site installation

Connect the power supply cable to the media converter BEFORE connecting to the outlet.

Install unit with PSU provided.  (Output 12 VDC regulated, 350 mA).

Install no more than two (2) media converters in series.

E-100BTX-FRL-03, E-100BTX-FRL-03(SC), E-100BTX-FRL-03(SM)

toward ne

Leave in default posit

Reviews: