Install the Slide-In-Module 

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing the media converter.  Failure to observe this
caution could result in damage to, and subsequent failure of, the media
converter.

To install the CSETF10xx-205 media converter slide-in-module:

1.

Locate an empty installation slot on the 

PointSystem™

chassis.

2.

Carefully slide the slide-in-module into the installation slot, aligning the
module with the installation guides.  

3.

Ensure that the module is firmly seated inside the chassis.

4.

Push in and rotate the attached panel fastener screw clockwise to secure
the module to the chassis front.

CFMFF100

CFMFF100

CETCF100

CFETF100

CFMFF100

SPD

PWR

FRX

CRX

FLNK

CLNK

100BASE-TX

RX

TX

100BASE-FX

Link Alert

E

D

0

50½

LA

PWR

RXF

RXC

LNK

COL

LKS

PWR

LKM

10BASE-2

10BASE-FL

LKS

PWR

LKM

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

Multimode

Singlemode

TX

RX

TX

RX

Multimode

Singlemode

TX

RX

TX

RX

I

0

TERM

INIT

RX

TX

LNK

PWR

CPSMM120

SERIAL

10BASE-T

R
E
S
E
T

I

0

PWR

SX

10

TX

100

ACT

panel fastener screw

Installation

Set the Jumper

The jumper is located on the circuit board.

Use small needle-nose pliers to set the jumper.  

Hardware The media converter settings such as

AutoCross and Link Pass-Through cannot be
changed.

Software

The media converter settings are determined
by the most-recently saved, on-board
microprocessor settings.

Software Mode

Hardware Mode

S

H

S

H

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

3

Installation 

-- Continued

Installing the Cable 

Fiber

1.

Locate or build 10/100Base-SX compliant fiber cable with male, two-
stranded TX to RX connectors installed at both ends.

2.

Connect the fiber cables to the CSETF10xx-205 media converter as
described: 

Connect the male TX cable connector to the female TX port.

Connect the male RX cable connector to the female RX port.

3.

Connect the fiber cables to the other device (another media converter,
hub, etc.) as described: 

Connect the male TX cable connector to the female RX port.

Connect the male RX cable connector to the female TX port.

Connect the fiber cable 
to the media converter
as shown.

Connect the fiber cable

to the other device

(media converter, 

hub, etc.) as shown

RX

TX

RX

TX

Copper

1.

Locate or build 10/100Base-TX compliant copper cables with male, RJ-45
connectors installed at both ends.

2.

Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the CSETF10xx-205 media converter.

3.

Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device (switch, workstation, etc.).

RJ-45 port

on the other device

(switch, work station, etc.)

RJ-45 port

on the media 

converter

Summary of Contents for CSETF1011-205

Page 1: ...ce is dependent upon the physical characteristics of the network installation The stand alone version of this media converter is SSETF10xx 205 For more information see the SSETF10xx 205 user s guide o...

Page 2: ...dware The media converter settings such as AutoCross and Link Pass Through cannot be changed Software The media converter settings are determined by the most recently saved on board microprocessor set...

Page 3: ...ink loss 4 which prevents the loss of valuable data unknowingly transmitted over an invalid link 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper lin...

Page 4: ...le Specifications The physical characteristics must meet or exceed IEEE 802 3 specifications Fiber Cable Bit Error Rate 10 9 Multimode fiber recommended 62 5 125 m Multimode fiber optional 100 140 85...

Page 5: ...SB RS232 RS422 RS485 DS1 DS3 Video Coax etc are NOT to be connected to inter building outside plant link segments that are subject to lightening transients or power faults 9 techsupport transition com...

Page 6: ...If persistent disconnect and reconnect either cable to restart the initialization process YES The media converter has selected 10 Mb s operation for the fiber link If this is not the correct speed di...

Page 7: ...ulations This digital apparatus does not exceed the Class A B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le...

Reviews: