Transition Networks CSETF1011-205 User Manual Download Page 1

User’s Guide

CSETF10xx-205 

Slide-in-Module Media Converter

• Ethernet and Fast Ethernet
• 10/100Base-TX to 10/100Base-SX

Transition Networks CSETF10xx-205 series
Ethernet and Fast Ethernet media converters
connect 10/100Base-TX twisted-pair copper cable
to 10/100Base-SX fiber-optic cable. The
CSETF10xx-205 is also designed to be installed in
a Transition Networks 

PointSystem™

chassis.

* Typical maximum cable distance.  Actual distance is dependent upon the

physical characteristics of the network installation.

The stand alone version of this media converter is SSETF10xx-205.  For more
information, see the SSETF10xx-205 user’s guide on-line at:  www.transition.com.

Installation  . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Cable Specifications  . . . . . . . . . . .7
Technical Specifications  . . . . . . . .8
Troubleshooting  . . . . . . . . . . . . . .9
Contact Us  . . . . . . . . . . . . . . . . .11
Compliance Information . . . . . . .12

Part Number

Port One - Copper
10/100Base-TX

Port Two - Fiber-Optic
10/100Base-SX

CSETF1011-205

RJ-45 
80 m 

(262 ft)*

ST, 850 nm multimode
2 km 

(1.2 mi.)*

@ 10 Mb/s 

60 m 

(197ft.)*

@ 100 Mb/s 

CSETF1013-205

RJ-45 
80 m 

(262 ft)*

SC, 850 nm multimode
2 km 

(1.2 mi.)*

@ 10 Mb/s 

60 m 

(197 ft.)*

@ 100 Mb/s 

Summary of Contents for CSETF1011-205

Page 1: ...ce is dependent upon the physical characteristics of the network installation The stand alone version of this media converter is SSETF10xx 205 For more information see the SSETF10xx 205 user s guide o...

Page 2: ...dware The media converter settings such as AutoCross and Link Pass Through cannot be changed Software The media converter settings are determined by the most recently saved on board microprocessor set...

Page 3: ...ink loss 4 which prevents the loss of valuable data unknowingly transmitted over an invalid link 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper lin...

Page 4: ...le Specifications The physical characteristics must meet or exceed IEEE 802 3 specifications Fiber Cable Bit Error Rate 10 9 Multimode fiber recommended 62 5 125 m Multimode fiber optional 100 140 85...

Page 5: ...SB RS232 RS422 RS485 DS1 DS3 Video Coax etc are NOT to be connected to inter building outside plant link segments that are subject to lightening transients or power faults 9 techsupport transition com...

Page 6: ...If persistent disconnect and reconnect either cable to restart the initialization process YES The media converter has selected 10 Mb s operation for the fiber link If this is not the correct speed di...

Page 7: ...ulations This digital apparatus does not exceed the Class A B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le...