8
24-Hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
CRS2F31xx-100
Technical Specifications
For use with Transition Networks Model CRS2F31xx-100 or equivalent
Data Rate
115 kB/s (asynchronous)
Dimensions
3.4" x 5.0" x 0.86" (86 mm x 127 mm x 22 mm)
Weight
3 oz. (91 g) (approximately)
Power Consumption
5 Watts
MTBF
2,613,860 hours (MIL217F2 V5.0) (MIL-HDBD-217F)
6,569,957 hours (Bellcore7 V5.0)
Environment
Tmra*:
0 to 50°C (32° to 122° F )
Storage Temp:
-15° to 65°C (5° to 149°F)
Humidity:
5 to 95%, non condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature. Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.
The information in this user’s guide is subject to change. For the most up-to-date
information on the CRS2F31xx-100 media converter, view the user’s guide on-
line at: www.transition.com
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and invisible laser radiation when open. Do not stare into
the beam or view directly with optical instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
-- Click the
“Transition Now”
link for a live Web chat.
9
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1.
Is the
P
(power) LED illuminated?
NO
•
Is the media converter inserted properly into the chassis?
•
Is the power cord properly installed in the chassis and in the grounded AC
outlet?
•
Does the grounded AC outlet provide power?
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the
RX
(copper) LED flashing?
NO
•
Disconnect and reconnect the RS-232 copper cable to restart the initialization
process.
•
Restart the attached device on the other end of the RS-232 cable to restart the
initialization process.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the
FL
(fiber) LED illuminated?
NO
•
Check the fiber cables for proper connection.
•
Verify that the TX and RX cables on the media converter are connected to the
RX and TX ports, respectively, on the other media converter.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 4.
4.
Is the
FL
(fiber) LED flashing?
YES
•
The media converter is in loop-back mode. To disable the loop-back function
in “Hardware” mode, set the loop-back switch to the "Norm" position. In
“Software” mode, at the SNMP interface, select “disable loop-back” option.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•