Transition Networks CRS2F3111-100 User Manual Download Page 5

8

24-Hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

CRS2F31xx-100

Technical Specifications

For use with Transition Networks Model CRS2F31xx-100 or equivalent

Data Rate

115 kB/s (asynchronous)

Dimensions

3.4" x 5.0" x 0.86" (86 mm x 127 mm x 22 mm)

Weight

3 oz.  (91 g) (approximately)

Power Consumption

5 Watts

MTBF

2,613,860 hours (MIL217F2 V5.0) (MIL-HDBD-217F)
6,569,957 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 50°C (32° to 122° F )

Storage Temp:

-15° to 65°C (5° to 149°F)

Humidity:

5 to 95%, non condensing

Altitude:

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature.  Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.

The information in this user’s guide is subject to change.  For the most up-to-date
information on the CRS2F31xx-100 media converter,  view the user’s guide on-
line at:  www.transition.com

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION:  

Visible and invisible laser radiation when open.  Do not stare into

the beam or view directly with optical instruments.

CAUTION: 

Use of controls, adjustments or the performance of procedures other

than those specified herein may result in hazardous radiation exposure.

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

9

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the 

P

(power) LED illuminated?

NO

Is the media converter inserted properly into the chassis? 

Is the power cord properly installed in the chassis and in the grounded AC
outlet?

Does the grounded AC outlet provide power?

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 2.

2.

Is the 

RX

(copper) LED flashing?

NO

Disconnect and reconnect the RS-232 copper cable to restart the initialization
process.

Restart the attached device on the other end of the RS-232 cable to restart the
initialization process.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 3.

3.

Is the 

FL

(fiber) LED illuminated?

NO

Check the fiber cables for proper connection.

Verify that the TX and RX cables on the media converter are connected to the
RX and TX ports, respectively, on the other media converter.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 4.

4.

Is the 

FL

(fiber) LED flashing?

YES

The media converter is in loop-back mode.  To disable the loop-back function
in “Hardware” mode, set the loop-back switch to the "Norm" position.  In
“Software” mode, at the SNMP interface, select “disable loop-back” option.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 5.

Summary of Contents for CRS2F3111-100

Page 1: ...physical characteristics of the network installation The stand alone version of the media converter is SRS2F31xx 100 For more information see the SRS2F31xx 100 user s guide on line at www transition...

Page 2: ...via a straight through RS 232 cable Set the switch to DCE configuration if the media converter is connected to a DTE device via a straight through RS 232 cable DCE Configuration techsupport transition...

Page 3: ...X FL Loop Norm CRS2F Panel Fastener Screw software mode hardware mode H S H S J2 J2 Power the Media Converter The media converter is powered through the PointSystem chassis techsupport transition com...

Page 4: ...oth the local and remote media converter NOTE In a managed network both the local and remote media converters must be set to software mode see page 4 techsupport transition com Click the Transition No...

Page 5: ...erein may result in hazardous radiation exposure techsupport transition com Click the Transition Now link for a live Web chat 9 Troubleshooting If the media converter fails isolate and correct the fai...

Page 6: ...ment w SNMP Management copper Fiber copper Remote Converter Local Converter Local Device Bit E rror Tes t E quipme nt w SNMP Management copper Fiber copper Remote Converter Local Converter Local Devic...

Page 7: ...de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communicati...