Troubleshooting

1.

Press the Reset button on the management module.  Does the
fault resolve itself?
NO

Proceed to step 2.

2.

Is the “Power” LED illuminated?
NO

Is the management module inserted properly into the chassis?

Is the chassis properly connected to the external power source.  

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES

Proceed to step 3.

3.

Is the “LNK” (link) LED illuminated?
NO

If the DB-9 serial port is being used for data transmission, check it for
proper connection.

If the RJ-45 Ethernet port is being used for data transmission, check it
for proper connection.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES

Proceed to step 4.

4.

Is  the “IN - LED 1” LED illuminated?
YES

The BIA (burned in address) has not gone through the read cycle.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600 .

NO

Proceed to step 5.

5.

Is the “IN-LED 2” LED illuminated?
NO

If there is no network activity, proceed to step 6.

Check the RJ-45 cascade cable(s) for proper connection.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600 .

YES

Proceed to step 6.

CPSMM-200 / CPSMM-210

10

24-hour Technical Support: 

1-800-260-1312

International: 

00-1-952-941-7600

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

11

Declaration of Conformity

Name of Mfg:

Transition Networks 

6475 City West Parkway, Minneapolis MN 55344 USA

Model:

CPSMM-200 Dual-Slot Master Management Module
CPSMM-210 Single-Slot Expansion Management Module

Part Number(s):

CPSMM-200, CPSMM-210

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the

CPSMM-200 

and 

CPSMM-210

to which this

declaration refers are in conformity with the following standards.

CISPR 22:1993; EN 55022:1994, A1:1995, A2:1997; Class A & B; FCC Part 15

Subpart B; EN 55024:1998; EN 61000-3-2:1995; EN 61000-3-3:1005

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

       July 8, 2001     

Stephen Anderson, Vice-President of Engineering

Date

Troubleshooting

-- Continued

6.

Is the “OUT-LED 2” LED illuminated?
NO

The processor inside the management module has not initialized.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600 .

NOTE: 

To Isolate faults involving data transmission, Please see the

“Troubleshooting” section of the 

FocalPoint™ 

Management Application

& CPSMM100 Firmware User’s Guide

on the enclosed application CD.

It can also be viewed on the Transition Networks website at:
www.transition.com.

Summary of Contents for CPSMM-200

Page 1: ...ase T RJ 45 Ethernet port In addition the CPSMM 200 has two RJ 45 ports in and out to accommodate stacking multiple PointSystem chassis Multiple chassis can be cascaded in this manner with a CPSMM 210 Single Slot Expansion Management Module installed in each subsequent chassis in the stack Installation 4 Network Management 6 Operation 7 Technical Specifications 9 Troubleshooting 10 Compliance Info...

Page 2: ... Ethernet Port RJ 45 Cascade Ports CPSMM 200 dual slot master management module techsupport transition com Click the Transition Now link for a live Web chat 3 CPSMM 210 Single Slot Expansion Management Module The figure below illustrates the components of the CPSMM 210 expansion management module A panel fastener screw that secures the management module to the Pointsystem chassis A POWER LED indic...

Page 3: ...g two CPSMC 200 dual slot master management modules into two adjacent chassis for redundant management Redundant management can also be set up with the two CPSMM 200 modules installed in the same chassis In this set up the two modules auto negotiate where one is the primary module while the other is in stand by mode If the primary module fails the stand by module automatically takes over and manag...

Page 4: ... Telnet server or Web browser Install and use the FocalPoint 2 0 management application See the FocalPoint 2 0 Management Application and CPSMM100 Firmware User s Guide on the enclosed application CD It can also be viewed on the Transition Networks website at www transition com Operation Reset Switch Both the CPSMM 200 and the CPSMM 210 have a reset switch which resets only the management module n...

Page 5: ...k the Transition Now link for a live Web chat 9 Technical Specification For use with Transition Networks models CPSMM 200 CPSMM 210 or equivalent Standards CISPR 22 1993 Class A B CE Mark CPSMM 200 Dimensions 3 4 x 1 72 x 5 0 86 mm x 44 mm x 127 mm Shipping Weight 6 oz 181 g approximate Power Consumption 3 3 Watts MTBF 144 000 hours MIL217F2 V5 0 MIL HDBK 217F 713 000 hours Bellcore7 V5 0 CPSMM 21...

Page 6: ...0 CPSMM 210 10 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 11 Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model CPSMM 200 Dual Slot Master Management Module CPSMM 210 Single Slot Expansion Management Module Part Number s CPSMM 200 C...

Page 7: ...rference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHO...

Reviews: