Transition Networks CGETF10XX-10X User Manual Download Page 2

2

CGETF10xx-10x

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600  

Part Number

Port One - Copper

Port Two - Single Fiber-Optic

CGETF1029-105

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1310 TX/1550 RX 
single mode, 20 km 

(12.4 miles)*

CGETF1029-106

RJ-45 1000Base-T
100 m 

(328 ft)

*

SC, 1000Base-LX, 1550 TX/1310 RX 
single mode, 20 km 

(12.4 miles)*

The CGETF1029-105 and the CGETF1029-106 are to be
installed in the same network, where one is the local converter
and the other is the remote converter.

CGETF1029-107

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1310 TX/1550 RX 
single mode, 40 km 

(24.8 miles)*

CGETF1029-108

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1550 TX/1310 RX 
single mode, 40 km 

(24.8 miles)*

The CGETF1029-107 and the CGETF1029-108 are to be
installed in the same network, where one is the local converter
and the other is the remote converter.

* Typical maximum cable distance. Actual distance is dependent upon the physical

characteristics of the network installation. 

(TX = transmit, RX = receive)

Installation 

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the jumper and the 4-position switch and when
installing the CGETF10xx-10x media converter into the 

PointSystem™

chassis.

Failure to observe this caution could result in damage to, and subsequent failure
of, the media converter.

Set the 3-position jumper

The jumper is located on the media converter circuit board.

Use small needle-nosed pliers or a similar device to set the jumper.  

Refer to the drawing below for the jumper positions.  

Hardware

The media converter mode is

determined by the 4-position switch
settings 

(as described on page 3)

.

Software

The media converter mode is

determined by the most-recently saved,
on-board microprocessor settings.

Software Mode

Hardware Mode

H

S

H

S

[email protected] -- Click the “Transition Now” link for a live Web chat.

3

Installation 

-- Continued

Set the 4-position switch

The 4-position switch is
located on the side of the
media converter.  

Use a small flat blade
screwdriver to set the
recessed switches.    

1. Twisted-Pair Full/Half Duplex Mode

up

= Full-Duplex on the copper link 

(see page 6).

down = Half-Duplex on the copper link 

(see page 6). 

2.

Pause 

up

= Enable Pause 

(see page 7)

.

down = Disable Pause.

3.

Link Pass-Through

up

= Enable Link Pass-Through 

(see page 6)

.

down = Disable Link Pass-Through.

4.

Fiber Auto-Negotiation

up

= Disable Auto-Negotiation for the fiber link

(default setting).

down = Enable Auto-Negotiation for the fiber link.

If the CGETF10xx-10x is connected via fiber to another CGETF10xx-10x, both
media converters must have the fiber Auto-Negotiation setting disabled

(switch 4 = up)

. Otherwise, the fiber-linked media converters will not link up.

When Fiber Auto-Negotiation is disabled 

(default setting)

:

Switches 1, 2 and 3 will function only if Fiber Auto-Negotiation is disabled.
The settings for Twisted-Pair Full/Half Duplex, Pause, and Link Pass-Through
can be set as needed using switches 1, 2 and 3.  

When Fiber Auto-Negotiation is enabled:
Switches 1, 2, and 3 will not function and the media converter adopts the
settings for Twisted-Pair Full/Half Duplex, Pause, and Link Pass-Through from
the media converter at the other end of the fiber cable.  

Fiber Auto-Negotiation allows the fiber interface to detect and subsequently
advertise the support abilities from the remote device. It is supported only
when the fiber is connected to a device with a negotiating port.  The process
is as follows:  
1.

The fiber interface detects the support abilities from the remote partner.

2.

These abilities are passed to the twisted-pair interface and advertised.

3.

Once the twisted-pair interface has a link at the highest common ability,
it passes the result to the fiber interface.

4.

The fiber interfaces then start advertising these abilities. At this point, the
link between the fiber and the negotiating port is complete.

Link Pass-Through:  up = Enable

Pause:  up = Enable

Copper Mode:  up = Full Duplex

1 2 3 4

Fiber Auto-Negotiation:

up =  Disable

Summary of Contents for CGETF10XX-10X

Page 1: ...single mode 10 km 6 2 miles CGETF1015 105 RJ 45 1000Base T 100 m 328 ft SC 1000Base LX 1310 nm single mode 25 km 15 5 miles CGETF1017 105 RJ 45 1000Base T 100 m 328 ft SC 1000Base LX 1550 nm single m...

Page 2: ...Installation Continued Set the 4 position switch The 4 position switch is located on the side of the media converter Use a small flat blade screwdriver to set the recessed switches 1 Twisted Pair Ful...

Page 3: ...FETF110 CFMFF100 LA PWR RXF RXC LNK COL SPD PWR FRX CRX FLNK CLNK 100BASE TX RX TX 100BASE FX Link Alert E D 0 50 LA PWR RXF RXC LNK COL LKS PWR LKM 10BASE 2 10BASE FL 10BASE T LKS PWR LKM Multimode S...

Page 4: ...titled Collision Domains on the Transition Networks website at www transition com 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media conver...

Page 5: ...00 1 952 941 7600 9 techsupport transition com Click the Transition Now link for a live Web chat Cable Specifications Continued Fiber Cable Continued CGETF1039 105 850 nm multimode Fiber Optic Transmi...

Page 6: ...1000Base SX LX port continue below If there is activity on the 1000Base SX LX port disconnect and reconnect the fiber cable to restart the initialization process Restart the workstation to restart th...

Page 7: ...Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der...