12
CBFTF10xx-14x
24-Hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate:
<10-9
Single mode fiber (recommended):
9 µm
Multimode fiber (recommended):
62.5/125 µm
Multimode fiber (optional):
100/140, 85/140, 50/125 µm
CBFTF1011-140
1300 nm multimode
CBFTF1013-140
1300 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
CBFTF1014-140
1310 nm single mode
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -31.0 dBm
max: -8.0 dBm
Link Budget:
16.0 dB
CBFTF1015-140
(long haul)
1310 nm single mode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
26.0 dB
CBFTF1016-140
(extra long haul)
1310 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CBFTF1017-140
(long wave length)
1550 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CBFTF1018-140
1300 nm multimode
Fiber-optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.5 dBm
max: -14.0 dBm
Link Budget:
14.5 dB
CBFTF1025-140
1310 nm single mode
Fiber-optic Transmitter Power:
min: -11.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -20.0 dBm
max: -3.0 dBm
Link Budget:
9.0 dB
CBFTF1029-140
1310 nm (TX) / 1550 nm (RX) simplex
CBFTF1029-141
1550 nm (TX) / 1310 nm (RX) simplex
Fiber-optic Transmitter Power:
min: -13.0 dBm
max: -6.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.0 dBm
max: -3.0 dBm
Link Budget:
19.0 dB
CBFTF1029-142
1310 nm (TX) / 1550 nm (RX) simplex
CBFTF1029-143
1550 nm (TX) / 1310 nm (RX) simplex
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.0 dBm
max: -3.0 dBm
Link Budget:
25.0 dB
The fiber optic transmitters on this device meets Class I Laser safety
requirements per IEC-825/CDRH standards and complies with 21
CFR1040.10 and 21CFR1040.11.
13
-- Click the
“Transition Now”
link for a live Web chat.
Cable Specifications
-- Continued
Copper Cable
Category 3:
(Minimum requirement for 10 Mb/s operation)
Gauge
24 to 22 AWG
Attenuation
11.5 dB/100m @ 5-10 MHz
Maximum Cable Distance
100 meters
Category 5:
(Minimum requirement for 100 Mb/s operation)
Gauge
24 to 22 AWG
Attenuation
22.0 dB /100m @ 100 MHz
Maximum Cable Distance
100 meters
• Straight-through or crossover twisted-pair cable may be used.
• Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
Technical Specifications
For use with Transition Networks Model CBFTF10xx-14x or equivalent.
Standards
IEEE 802.3™
Data Rate
10 Mb/s, 100 Mb/s
Dimensions
3.4" x 1.72" x 5.0" (86 x 44 x 127 mm)
Weight
6 oz. (181 g) (approximate)
Power Consumption
4.95 watts
MTBF
1,023,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
4,660,000 hours (Bellcore7 V5.0)
Packet Size:
Memory: 256K bytes (2 Mbit)
Unicast MAC address: 4K bytes
Maximum packet size: 1536 bytes
Environment
Tmra*:
0 to 60°C (32 to 140°F )
Storage Temp:
-20 to 85°C (-4 to 185°F)
Humidity:
5 to 95%, non condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module depends
on the physical characteristics and the installation configuration of the Transition Networks
PointSystem™ chassis in which this slide-in-module will be installed.
The information in this user’s guide is subject to change. For the most up-to-date
information, please see the user’s guide on-line at: www.transition.com