background image

Trademark Notice

All trademarks and registered trademarks are the property of their respective owners.

Copyright Restrictions

© 2001-2003, 2005 Transition Networks.
All rights reserved.  No part of this work may be reproduced or used in any form or by any
means - graphic, electronic, or mechanical - without written permission from Transition
Networks.
Printed in the U.S.A.

33222.E

Contact Us

Technical Support

Technical support is available 24 hours a day
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition Now

Chat live via the Web with Transition Networks Technical Support.
Log onto 

www.transition.com

and click the 

Transition Now

link.

Web-Based Seminars

Transition Networks provides seminars via live web-based training.
Log onto 

www.transition.com

and click the 

Learning Center

link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff.

[email protected]

Address

Transition Networks
6475 City West Parkway
Minneapolis, MN  55344, USA
telephone:

952-941-7600

toll free:

800-526-9267

fax:

952-941-2322

Declaration of Conformity

Name of Mfg:

Transition Networks 

6475 City West Parkway, Minneapolis MN 55344 USA

Model:

CBFTF10xx-12x Series Media Converters

Part Number(s):

CBFTF1011-120, CBFTF1013-120, CBFTF1014-120, CBFTF1015-120, 
CBFTF1016-120, CBFTF1017-120, CBFTF1018-120,  CBFTF1025-120,
CBFTF1029-120, CBFTF1029-121, CBFTF1029-122,  CBFTF1029-123

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the

CBFTF10xx-12x 

to which this declaration refers is

in conformity with the following standards.

CISPR 22: 1993; EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; 

EN 61000-3-2:1995; EN 61000-3-3:1995; 21 CFR subpart J

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

_April 16, 2001_____

Stephen Anderson, Vice-President of Engineering

Date

Summary of Contents for CBFTF1011-120

Page 1: ...m multimode 2 km 1 2 miles CBFTF1025 120 RJ 45 100 m 328 ft MT RJ 1310 nm single mode 5 km 3 1 miles User s Guide CBFTF10xx 12x Slide in Module Media Converter Copper to Fiber 10 100 Bridging 6 Port 5 copper 1 fiber 10 100Base TX to 100Base FX The CBFTF10xx 12x 6 port Ethernet fast Ethernet bridging media converter is designed to be installed into a Transition Networks PointSystem chassis and allo...

Page 2: ... Pair Port 3 TP3 Installation Continued Set the Dip Switches The dip switches are located on the side of the media converter Use a small flat blade screwdriver or a similar device to set each dip switch SW1 switches 1 6 Dip switches 1 2 and 3 apply only to twisted pair copper port 1 TP1 Dip switch 4 applies to fiber port 1 F1 Dip switch 5 applies to all twisted pair copper ports TP1 TP2 TP3 TP4 TP...

Page 3: ...Config Switches set apply only to twisted pair copper port 2 TP2 1 Twisted Pair Auto Negotiation UP Enabled The media converter advertises ALL rate and mode capabilities to the network 100Mb s full duplex 100Mb s half duplex 10Mb s full duplex 10Mb s half duplex DOWN Disabled The bridging media converter does not advertise the rate and mode capabilities to the network Switch 2 and switch 3 are the...

Page 4: ...oprocessor settings Software Mode Hardware Mode H S H S techsupport transition com Click the Transition Now link for a live Web chat 7 Installation Continued Install the Copper and Fiber Cables If half duplex mode is used refer to the 512 Bit Rule see page 9 If full duplex mode is used the 512 Bit Rule does not apply The cable lengths are constrained by the cable requirements see pages 1 and 2 Twi...

Page 5: ...duplex network the maximum cable lengths are determined by the round trip delay limitations of each fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e g a terminal switch or router The 512 Bit Rule determines the maximum length of cable permitted by calculating the round trip delay in bit times BT of a particular collision domain If the result ...

Page 6: ...ardless if the copper cable is MDI or MDI X configuration Transition networks recommends leaving the device in the default enable mode techsupport transition com Click the Transition Now link for a live Web chat 11 Cable Specifications Continued The physical characteristics must meet or exceed IEEE 802 3 specifications Fiber Cable Bit Error Rate 10 9 single mode fiber recommended 9 µm Multimode fi...

Page 7: ...EEE 802 3 Data Rate 10 Mb s 100 Mb s Dimensions 3 4 x 1 75 x 5 0 86 x 43 x 182 mm Weight 6 oz 181 g approximate Power Consumption 4 95 watts MTBF 1 023 000 hours MIL217F2 V5 0 MIL HDBD 217F 4 660 000 hours Bellcore7 V5 0 Packet Size Unicast MAC addresses 4K Memory 256K bytes 2 Mbit Maximum packet size 1536 bytes Environment Tmra 0 to 60 C 32 to 140 F Storage Temp 20 to 85 C 4 to 185 F Humidity 5 t...

Page 8: ...ironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Re...

Page 9: ...anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model CBFTF10xx 12x Series Media Converters Part Number s CBFTF1011 ...

Reviews: