Transition Networks C4TEF1011-100 User Manual Download Page 2

2

C4TEF10xx-10x

Technical Support: 

1-800-260-1312

International: 

00-1-952-941-7600

(24 hours)

T1/E1

Link

Link

Link

Link

AIS

AIS

AIS

AIS

TX

RX

C4TEF

LKF

PWR

1

2

3

4

5

6

Fiber Port

RS-232

T1/E1Ports

Part Number

Fiber-Optic 

- single fiber, single mode, 100Base-FX

C4TEF1029-100 

SC, 1310 mn (TX)/1550 nm (RX), 20 km (12.4 miles)*

C4TEF1029-101 

SC, 1550 mn (TX)/1310 nm (RX), 20 km (12.4 miles)*

C4TEF1029

-100

and C4TEF1029

-101

are intended to be installed in the same link

where one is the local converter and the other is the remote converter.

Installation

NOTE:  

Due to proprietary communication over fiber, the C4TEF10xx-10x is

required to be installed in pairs, where one is the local converter and the other is
the remote converter.

Copper and Fiber Ports

The figure below illustrates the locations of the fiber port, the RS-232 port, and
the four (4) T1/E1 ports.  

NOTE:  

An 

RS-232 cable 

with a 6-pin DIN connector and a DB-9 connector is

included with the C4TEF10xx-10x media converter.

C4TEF1029-102 

SC, 1310 mn (TX)/1550 nm (RX), 40 km (24.8 miles)*

C4TEF1029-103 

SC, 1550 mn (TX)/1310 nm (RX), 40 km (24.8 miles)*

C4TEF1029

-102

and C4TEF1029

-103

are intended to be installed in the same link

where one is the local converter and the other is the remote converter.

* Typical maximum cable distance. Actual distance is dependent upon the

physical characteristics of the network.  (TX) = transmit, (RX) = receive

3

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

Installation 

-- Continued

Configuration Switches

The C4TEF10xx-10x media converter has two (2) sets of configuration switches.  

Set #1 is on the upper circuit board and sets the 

T1/E1 options

.

Set #2 is on the lower circuit board and sets the 

serial options

.

Use a flat blade screwdriver to set the switches as shown:

Switch Set #1 - T1/E1 Options

1, 2, 3, 4 - Line Settings 

Switches 1, 2, 3, and 4 are used to setup the line settings for the T1/E1 ports.  The
selected setting applies to all four (4) T1/E1 channels.

Switch Set #1:  T1/E1 Options

Switch Set #2:  Serial Options

Key:

up

down

DSX-1, 100 ohm, 266-399 ft. (81-122 m)

DSX-1, 100 ohm, 399-533 ft. (122-162 m)

DSX-1, 100 ohm, 0-133 ft. (0-40.5 m)

DSX-1, 100 ohm, 133-266 ft. (40.5-81 m)

1 2

DS1, 100 ohm, 0 dB LBO

DS1, 100 ohm, -7.5 dB LBO

DSX-1, 100 ohm, 533-655 ft. (162-200 m)

J1, 110 ohm, 0-655 ft. (0-200 m)

3

E1, 120 ohm

DS1, 100 ohm, -15 dB LBO

DS1, 100 ohm, -22.5 dB LBO

4

1 2 3 4

Summary of Contents for C4TEF1011-100

Page 1: ...e sent over the fiber interface simultaneously The C4TEF10xx 10x is designed to be installed in pairs For example install one C4TEF1011 100 as the local media converter and another C4TEF1011 100 as the remote media converter All C4TEF10xx 10x models have the following copper connectors The various fiber connectors are available on separate models Both duplex and single mode fiber optic converters ...

Page 2: ... km 24 8 miles C4TEF1029 102 and C4TEF1029 103 are intended to be installed in the same link where one is the local converter and the other is the remote converter Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network TX transmit RX receive 3 techsupport transition com Click the Transition Now link for a live Web chat Installation Continued Co...

Page 3: ...rier signal This function is un framed and applies to ALL channels both copper and fiber down Disables the transmit AIS function 10 RS 232 Port Mode up Data port mode normal operation Transmits data to a desk top computer or other data collection device down Local auxiliary management mode See the SNMP section page 11 for the commands that are supported via the RS 232 connector up down Enable Disa...

Page 4: ...Jumper The hardware software header J11 is located on the circuit board Use a small needle nose pliers to change the jumper position currently in the software position Install the Slide in Module CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing the C4TEF10xx 10x slide in module media converter Failure to observe this caution could result in damage to ...

Page 5: ...nnector to the media converter as shown Connect the DB 9 connector to the computer RS 232 data cable enclosed Dry Contact Relay All four T1 E1 ports are equipped with an RJ 48 dry contact relay The relay closes if the power is lost or if any of the individual T1 E1 links are lost The operational rating on pins 3 and 6 are 0 30 VDC 100 mAmp maximum relay 3 6 RJ 48C connector T1 E1 port 9 techsuppor...

Page 6: ...e to a local C4TEF10xx 10x slide in module media converter that is installed in a managed Transition Networks PointSystem chassis See the list of SNMP commands below SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring Media c...

Page 7: ...nsmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB C4TEF1013 100 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB C4TEF1014 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sen...

Page 8: ...ols adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure 15 techsupport transition com Click the Transition Now link for a live Web chat Troubleshooting If the media converter fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED illuminat...

Page 9: ... mode enter the local T1 E1 loop back command at the remote converter Use a bit error test unit to run a bit error test Fiber T1 T1 Local Converter Remote Converter Bit Error Test Equipment Remote Device Fiber T1 T1 Local Converter Remote Converter Bit Error Test Equipment Remote Device Fiber T1 T1 Local Converter Remote Converter Remote Device Bit Error Test Equipment Fiber T1 T1 Local Converter ...

Page 10: ...diate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed ...

Page 11: ...their respective owners Copyright Restrictions 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33306 C ...

Reviews: