Transition Networks C/TR-CF-01(SM) User Manual Download Page 3

6

1. Is the p(o)w(e)r LED on the media converter illuminated?

NO

Is the Slide-In-Module properly connected to the Media Conversion
Center chasis backplane?

Is the Power Supply Module properly connected both to the Media
Conversion Center chasis backplane and to the AC outlet? 

Are the two sides of the network the same speed: 4Mb/s or
16Mb/s?

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 2.

2. Is the S(ignal) D(etect) C(opper) LED illuminated?

NO

Check twisted pair cables for proper connection.

Check RJ-45 Pinning Switch for correct twisted pair cable
configuration.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 3.

3. Is the S(ignal) D(etect) F(iber) LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are
connected to RX and TX ports, respectively, on other device.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 4.

4. Is the Ins(erted) LED illuminated?

NO

Restart the workstation to restart the initialization process.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

TROUBLESHOOTING SUGGESTIONS

NOTE: The switches are located directly on the C/TR-CF-01 Slide-In-
Module circuit board.

Switch settings shown below are used when configuring straight-
through/RO or crossover/RI cable configuration, network installation mode
(1-4), active or passive state of attached concentrator, and network
compliance or non-compliance with the IEEE 802.5j standard.

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

Mode 1: 

Selected when installing

media converter between station

and fiber extension.

Mode 2: 

Selected when installing

media converter between fiber extension

and active concentrator RI or lobe port.

Mode 3: 

Selected when installing

media converter between fiber extension

and passive concentrator RI port.

Mode 4: 

Selected when installing

media converter between passive/active

concentrator RO port and fiber extension.

Active: 

Selected when installing

media converter to active concentrator

Ring port.

Passive: 

Selected when installing

media converter to passive concentrator

Ring port.

802.5j: 

Selected when installing

media converter in 802.5j-compliant

network.

Non-802.5j: 

Selected when installing

media converter in non-802.5j-compliant

network.

C(oncentrator)

/R(ing) O(ut):

Selected when

installing

media converter

to active/passive

concentrator

RO port.

S(tation)

/R(ing) I(n):

Selected when

installing

media converter

to active/passive

concentrator

RI port.

SWITCH SETTINGS

C/TR-CF-01

Summary of Contents for C/TR-CF-01(SM)

Page 1: ...phic electronic or mechanical without written permission from TRANSITION Networks Trademark Notice All registered trademarks and trademarks are the property of their respective owners 33087 D Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichun...

Page 2: ...itivity min 32 5 dBm max 14 0 dBm Wavelength 1300nM Bit error rate 10 9 Maximum Cable Distance 15 kilometers Connector Characteristics ST type connectors SMA type available TWISTED PAIR CABLE AND CONNECTOR SPECIFICATIONS Cable Characteristics Category 3 wire or better is required category 5 wire is recommended Either shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE F...

Page 3: ...E The switches are located directly on the C TR CF 01 Slide In Module circuit board Switch settings shown below are used when configuring straight through RO or crossover RI cable configuration network installation mode 1 4 active or passive state of attached concentrator and network compliance or non compliance with the IEEE 802 5j standard 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 ...

Page 4: ...F 01 UTP STP Fiber Token Ring Twisted Pair to Fiber Media Converter RJ 45 Pinning Config Switches 1 2 3 4 2 kilometers multimode 15 kilometers singlemode Active Concentrator RI RO Active Concentrator RI RO Active Concentrator RO to Active Concentrator RI C RO S RI 1 2 3 4 C RO S RI 1 2 3 4 Set RJ 45 switch to C RO Set Switch 1 2 to Mode 4 Set Switch 3 to Active Set Switch 4 according to network 80...

Reviews: