C/E-PSW-SX-01

EXAMPLE DIP SWITCH SETTINGS:

TWISTED-PAIR AUTO-NEGOTIATION:

Set auto-negotiation (DIP switch #1) to select auto-
negotiation: ON=UP

Set twisted-pair full-duplex/half-duplex (DIP switch #2) to
select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3) to
select 100BASE-TX: ON=UP

TWISTED-PAIR FULL-DUPLEX 100BASE-TX:

Set auto-negotiation (DIP switch #1) to de-select auto-
negotiation: OFF=DOWN

Set twisted-pair full-duplex/half-duplex (DIP switch #2) to
select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3) to
select 100BASE-TX: ON=UP

TWISTED-PAIR 10BASE-T WITH MODE AUTO-NEGOTIATION:

Set auto-negotiation (DIP switch #1) to select auto-
negotiation: ON=UP

Set twisted-pair full-duplex/half-duplex (DIP switch #2) to
select full-duplex: ON=UP

Set twisted-pair 10BASE-T/100BASE-TX (DIP switch #3) to
select 10BASE-T: OFF=DOWN

FIBER FULL-DUPLEX 100BASE-SX:

Set fiber full-duplex/half-duplex (DIP switch #4) to select
full-duplex: ON=UP

FIBER HALF-DUPLEX 100BASE-SX:

Set fiber full-duplex/half-duplex (DIP switch #4) to select
half-duplex: OFF=DOWN

Connecting Fiber Cable to TX/RX Connector
(100BASE-SX)

100BASE-SX AND THE FAST ETHERNET COLLISION DOMAIN

Refer to the 512-Bit Rule (page 7) before installing half-duplex

100BASE-SX cable.

Using full-duplex fiber cable avoids collision domain

considerations and extends distances up to 2 kilometers
(multimode) or up to 20 kilometers (singlemode).

NOTE: A Fast Ethernet collision domain can have ONLY ONE

CLASS I repeater OR TWO CLASS II repeaters.

INSTALLING CABLE
To install 100BASE-SX cable:

1. Locate or build 100BASE-SX cables:

100BASE-SX compliant (page 11)

with male transmit (TX) and receive (RX) fiber connectors

installed at both cable ends.

2. Connect transmit cable connector at one end of fiber cable to

bridging media converter connector marked with an “outbound”
arrow; connect receive cable connector to bridging media
converter connector marked with an “inbound” arrow.

3. Connect other end of cable installed at transmit (TX) connector of

bridging media converter to receive (RX) connector on network
device; connect other end of cable installed at receive (RX)
connector of bridging media converter to transmit (TX) connector
on network device.

Powering the Bridging Media Converter

To power ON the bridging media converter:

1. Locate power receptacle on back of bridging media converter

2. Connect the bridging media converter power connector end of the

power supply adapter to the power receptacle on the back of the
Transition Network’s bridging media converter.

3. Connect the external power connector end of the power supply

adapter to external AC power. 

NOTE: After the power supply adapter is connected to the bridging media
converter and to external power, the green Power LED is illuminated.

UP UP UP

DOWN

UP UP

UP

UP

DOWN

UP

DOWN

Summary of Contents for C/E-PSW-SX-01(SC)

Page 1: ...cal without written permission from TRANSITION Networks Trademark Notice All registered trademarks and trademarks are the property of their respective owners 33104 B Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften d...

Page 2: ...ILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 6 5 dB 100 10 MHz Differential Characteristic Impedance 100 Ω 15 Category 5 Gauge 24 to 22 AWG Attenuation 22 dB 100 100 MHz Differential Characteristic Impedance 100 Ω 15 Maximum Cable Distance 100 meters 330 feet 11 2 Link UTP STP Fiber Link FDX Power 100 10BASE T 100BASE SX RATE CONVERSION The two port Ethernet Fast Ethernet bridging me...

Page 3: ...tings shown below are set to configure the bridging media converter for the site installation To set network speed s and operating mode s use a VERY small flatblade screwdriver or similar device and refer to the table at the left and to the examples on the next page to set DIP switch for the site installation NOTE Auto negotiation is designed so that a twisted pair link will not become operational...

Page 4: ... domain considerations and extends distances up to 2 kilometers multimode or up to 20 kilometers singlemode NOTE A Fast Ethernet collision domain can have ONLY ONE CLASS I repeater OR TWO CLASS II repeaters INSTALLING CABLE To install 100BASE SX cable 1 Locate or build 100BASE SX cables 100BASE SX compliant page 11 with male transmit TX and receive RX fiber connectors installed at both cable ends ...

Page 5: ...age 7 with RJ 45 plug connectors installed at both cable ends 2 Connect RJ 45 plug connector at one end of 10BASE T or 100BASE TX cable to bridging media converter RJ 45 jack connector 3 Connect RJ 45 plug connector at other end of 10BASE T or 100BASE TX cable to RJ 45 jack connector on network device Installing Slide In Module s CAUTION Wear a grounding device and observe electrostatic discharge ...

Page 6: ...arates collision domain so the 512 bit rule applies separately to each 100BASE TX or 100BASE SX half duplex collision domain A segment is the cable connection between interfaces A transmission path between any two terminal devices including the Transition Networks Switch in the same collision domain can consist of no more than five segments To assign segment numbers to cable connections determine ...

Reviews: