background image

For assistance in installing, using, or
maintaining the TRANSITION Networks
Model 0400 Ethernet Pocket Hub,
contact TRANSITION Networks
Technical Support 

at:

(800) 260-1312

or contact your local distributor.

7333.D

Pocket Hub

Ethernet

(E-TBT-HB-0400)

Model 0400

MODEL 0400 ETHERNET POCKET HUB

SPECIFICATIONS

Standards

IEEE 802.2, 802.3

Physical

Dimensions

4.80" X 2.77" X 0.95"

(122mm x 70mm x 24mm)

Power Supply Adapter

AC Input:

PN

Requirement

Location

3518

120 volts, 60 hertz, 28 watts

USA/Canada/Mexico

3516

230 volts, 50 hertz, 28 watts

Europe

3514

100 volts, 50-60 hertz, 28 watts Japan

3517

240 volts, 50 hertz, 28 watts

United Kingdom

3515

240 volts, 50 hertz, 28 watts

Australia

DC Output:

12 volts at 500 mA maximum.

MTBF

47,000 hours

Environment

Temperature:

0-50°C (32° to 122° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Warranty

5 years

Model 0400

17

Summary of Contents for 400

Page 1: ...02 3 Physical Dimensions 4 80 X 2 77 X 0 95 122mm x 70mm x 24mm Power Supply Adapter AC Input PN Requirement Location 3518 120 volts 60 hertz 28 watts USA Canada Mexico 3516 230 volts 50 hertz 28 watts Europe 3514 100 volts 50 60 hertz 28 watts Japan 3517 240 volts 50 hertz 28 watts United Kingdom 3515 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 500 mA maximum MTBF 47 000 hours Env...

Page 2: ...munikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10Base2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed ...

Page 3: ...Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10BaseFL Cable Characteristics Fiber Optic Cable Recommended 62 5 125 µm multimode fiber Optional 100 140 µm multimode fiber 85 125 µm multimode fiber 50 125 µm mult...

Page 4: ...l not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of defective items 1 Locate the serial number s of the item s to be returned 2 Determi...

Page 5: ... WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS RE...

Page 6: ...ed Are network interface cards properly configured Technical Support Contact For assistance in fault isolation and in maintaining the 0400 Pocket Hub contact Technical Support 800 260 1312 or your local distributor 0400 Ethernet Pocket Hub Connectors and Status LEDs RJ 45 Connectors Four 4 10BaseT RJ 45 jack connectors are located at one end of the 0400 Pocket Hub The RJ 45 jacks support connectio...

Page 7: ...S The site for the 0400 Ethernet Repeater Hub must provide AC power outlet for each Hub Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone lines...

Page 8: ...ment When connecting Pocket Hubs the transmission path between any two Data Terminating Equipment DTE terminals can consist of no more than five segments To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the termina...

Page 9: ...r 10BaseT wall plate 1 Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 Straight through 10BaseT Crossover 10BaseT Ensuring Correct 10BaseT Configuration The 10BaseT cable and RJ 45 jacks for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 jacks for Hub to Hub connections must be configured as crossover 1 8 RJ 45PLUG RJ 45JACK 1 8...

Page 10: ...et Hub female AUI connector 1 Locate or build IEEE 802 3 compliant AUI drop cable 2 Connect AUI drop cable male DB 15 connector to the Pocket Hub AUI connector 3 Connect AUI drop cable female DB 15 connector to the AUI port on a transceiver or media attachment unit MAU Connecting10BaseT Cable To connect 10BaseT Cable to Pocket Hub RJ 45 connectors 1 Locate or build 10BaseT cables with the followin...