GPR battery charging
Getting Started
GPR battery charging
Each antenna unit is equipped with the sealed lead acid rechargeable battery (12 V, 7 Ah). The power supply
of the antenna unit prevents the deep discharge of the battery. The battery charge level is indicated in the
Status bar of the Main window of the Synchro3 software the battery.
When the battery voltage is low and close to the critical value, the power supply begins beeping. When the
battery voltage is below the cut-off threshold (10.8V) the power supply will turn the antenna unit off but beep
sound will continue ringing twice per second. That indicates the normal state of GPR and the necessity of
battery charging.
For battery charging use the charger that is included in GPR set.
Charging the battery of VIY3-300 or VIY3-125 GPR
For charging the battery of VIY3-300 or VIY3-125 GPR you should connect the charger plug to the GPR
DATA socket, and then plug the charger to the AC power (220-240V AC, 50-60 Hz).
9
To get more information please read the charger User manual that is in the charger set.
Charging the battery of VIY3-500 or VIY3-700 GPR
For charging the battery of VIY3-500 or VIY3-700 GPR you should connect the charger plug to the DATA
socket, located on the cover of Battery Box.
Then plug the charger to the AC power (220-240V AC, 50-60 Hz).
9
To get more information please read the charger User manual that is in the charger set.