Set-up and Placement
Use the IN5120 in-tool ionizing blower in proximity to
a static sensitive area or object. The unit can be set on
the workstation or mounted to a structure, using the u-
shaped mounting bracket and hardware. Point the unit at
the area to be protected.
Power Connection
Connect the AC adapter to the main unit, and plug it
in an AC socket.
(Caution: Do not substitute an-
other AC adapter without consulting the factory)
.
Make certain the unit is grounded.
Turn the unit on to start the corona process. The ion-
izer creates a continuous stream of positive and
negative air ions. The ionized airflow is directed
through the front grill. Charged objects in the ioniza-
tion area are rapidly neutralized .
The ion airflow is adjustable using the fan speed con-
trol knob.
The red alarm indicator light illuminates in the event
of a problem with the high voltage power output.
Turn the power switch off after operation.
Caution
!
Do not use this ionizer in an explosive environ-
ment! Corona ionizers produce a weak plasma
that can cause ignition in explosive environ-
ments.
3