background image

 

Packing list:

 

 

BFN 801 ionizing blower 

 

Power cord 

 

Instruction manual 

 

Certificate of Conformance 

Power Input 

120 V AC, 60 Hz., 36W 
220 V AC, 50Hz. 

 
Dimensions

   

 

7.0” W x 10.25” H x 3.75” D 
(17.8W x 26.0H x 9.5D cm)

 

 
Weight 

 

 

8.25 lb (3.75 kg)

 

 
Air Volume   

 

50 CFM – 100 CFM (low— high) 

RH Operating Range 

 

20-60%, non-condensing  

 

Product Specifications 

BFN 801 Charge Decay Efficiency  

(Discharge Time)

 

Black: Hi Fan Speed 

Red: Low Fan Speed 

1

1.

2.

1

1

1

2

3

1

1

1

1

2

3

1’ 

2’ 

3’ 

4’ 

5’ 

Tested in accord with 

 ANSI/ESD STM3.1-2006 

Discharge times de-

termined as per EOS/

ESD Standard No.3 

using  6” x6” 20 pF 

charge plate monitor. 

Discharge times are in 

seconds from 1000V 

to 100 V, Discharge 

times are slightly 

longer for 230V, 50 Hz 

 

Indicators   

 

ON/OFF status light  indicator, 
detects presence of HV on emit-
ter points

 

 

Audible Noise 

 

44dB(A) (Distance 1 meter) 

Enclosure 

 

 

Steel 

Finish 

Powder coat, off white

 

Approvals 

 

CE

 

Effective Coverage 

1’x5’ area coverage 

 
Balance 

 

 

0

 

+10 volts

 

 

Decay Time   

 

< 2 seconds @12”, 1000V-
100V, fan speed on high 
 

Temperature 

 

32-122° F (0-50° C)

 

Summary of Contents for BFN 801

Page 1: ...T R A N S F O R M I N G T E C H N O L O G I E S L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Static Eliminators BFN 801 Ionizing Blowers Instruction Manual BFN...

Page 2: ...scription BFN Series Ionizers Dependable Balanced and Fast BFN AC ionizers from Transforming Technologies are built to last Re liable AC ionization technology is combined with supe rior mechanical des...

Page 3: ...before removing the finger guards Do not open or attempt to repair any BFN series product Breaking the manufacturing seal will void warranty BFN 801 Bench top Blower Model The BFN 801 bench top ionizi...

Page 4: ...9 1 1 2 4 6 5 7 9 1 1 1 2 3 3 6 1 1 1 1 2 3 1 2 3 4 5 Tested in accord with ANSI ESD STM3 1 2006 Discharge times de termined as per EOS ESD Standard No 3 using 6 x6 20 pF charge plate monitor Discharg...

Page 5: ...rds and the fan assembly Emitter point cleaning affects the static decay ability of the ionizer and is important for maintaining its op timal performance Note Do not insert any object into the air inl...

Page 6: ...eaning All BFN series ionizing blowers offer convenient cleaning of the internal fan assembly Use the following procedure to maintain cleanliness Note Always disconnect the ionizer from the power sour...

Page 7: ...ter removing both front and rear fan guards the emit ter points and fan assembly will be unobstructed for easy deep cleaning Use a soft brush Isopropyl Alcohol and compressed air to remove any foreign...

Page 8: ...fan guard down D Lightly pull the very bottom of the rear fan guard downward with your thumb to lock it securely A B C Air Outlet Assembly A Slide the slot on the upper back side of the front fan gua...

Page 9: ...assure proper functioning of the product Periodic Verification BFN ionizer have no user serviceable parts and the technology requires no calibration because of the inher ently stable ionization output...

Page 10: ...rom the date of shipment Liability is limited to servicing after evaluating repairing or replacing any product returned to Transform ing Technologies The company does not warrant damage due to misuse...

Page 11: ...o tect their products and processes from the many serious problems associated with static electricity Transforming Technologies offers a wide range of unique and outstanding products to detect pro tec...

Page 12: ...Phone 419 841 9552 Fax 419 841 3241 E mail info transforming technologies com 3719 King Rd Toledo Ohio 43617 TRANSFORMING TECHNOLOGIES LLC...

Reviews: