background image

www.prolight.co.uk

HS2 Hybrid Distribution Splitter

 

User Manual

6

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Also remember that DMX cable must be daisy chained and cannot be split.

Summary of Contents for HS2 Hybrid Distribution Splitter

Page 1: ...Order code BOTE73 HS2 Hybrid PowerCON DMX Distribution Splitter User Manual ...

Page 2: ...the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is 240V AC 50Hz Make sure that the power cable is never crimped or damaged Check the equipment...

Page 3: ...R output per channel Each DMX output features an independent driver 100 electrical isolation between all inputs outputs 2 way PowerCON power distributor with one input and two outputs M10 rigging point Safety bond point Rugged steel chassis HS2 Hybrid PowerCON DMX Distribution Splitter Specifications Power supply 240V 50Hz Fuse F1A 250V Dimensions 61 x 160 x 175mm Weight 1 1kg Order code BOTE73 HS...

Page 4: ...0V 07 Earth point 08 Safety eye 09 M10 rigging point In the box 1 x HS2 distribution splitter 1 x power cable 1 x user manual Technical specifications HS2 Hybrid PowerCON DMX Distribution Splitter DMX OUTPUT 1 DMX OUTPUT DC POWER OUTPUT 1 240V 50Hz POWER OUTPUT 2 240V 50Hz MAX 20A TOTAL LOAD POWER INPUT 240V 50Hz DMX INPUT FUSE F1A 250V DMX OUTPUT 2 DMX OUTPUT DC 04 06 10 02 07 01 03 09 05 ...

Page 5: ...l cable may be connected with up to 32 fixtures per signal line and up to 100m cable length Connect the HS2 to a suitable 240VAC 50Hz mains supply via the PowerCON mains inlet LED indicators The HS2 is fitted with signal and DC indicators Under normal conditions with DMX signal passing through the unit both LEDs will be illuminated The DMX LED indicates the presence of a DMX signal The DC LED indi...

Page 6: ...at travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission wh...

Page 7: ...r own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour Special note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Using a cable terminator will decreas...

Page 8: ...revent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for enviro...