background image

 

BASIC OPERATION 

 
Getting Started – Cabled Systems 

 

1.  Press and hold the ON/PRINT key on the digital indicator unit for two seconds. 

After a brief initialization period, the scale will revert to a zero (“0”) weight display. 

 
Your scale is now ready for operation! 

 
 

Getting Started – Wireless Systems 

 

1.  Switch on the TI-500RFTM weighing module(s) by pressing the BLUE button once

The 

blue LED will turn solid for a few seconds and then start to flash. 

2.  Next press and hold the ON/PRINT key on the digital indicator unit for two seconds. 

After a brief initialization period, the scale will revert to a zero (“0”) weight display. 

 
Your wireless scale is now ready for operation! 

 
 

Operation – TI-700  

Before weighing it is necessary to check if the scale is unloaded and indicating zero weight in 
the desired unit of measure, for example lb for pounds. 

If the indicator is not displaying the desired unit of measure, press the UNITS key repeatedly un-
til it is indicated, e.g. lb for pounds, kg for kilograms, etc.  

The indicator features an automatic zero correction meaning that small deviations will be zeroed 
automatically. If the indicator does not automatically determine the zero point, please press the 
ZERO/OFF key once briefly.  
 
 

Operation – TI-500 RFTM  

 
The TI-500 RFTM contains two buttons and one LED.  

  The BLUE button is used to power up the RF weighing module 

  The RED button is used to immediately power down the RF weighing module 

 
The TI-500 RFTM has several operating modes to save battery life and also to alert the user 
when it’s time to replace the batteries. You can determine the operating mode by observing the 
blinking behavior of the blue LED: 
 

LED Functionality – Blinking interval 

During Power-up (Initialization) 

ON for 5 seconds 

 

 

 

FULL BATTERY 

Blink interval 

 

Working Mode 

1.5 seconds 

 

Sleep Mode (power savings) 

4 seconds 

 

 

 

 

LOW BATTERY 

Blink interval 

 

Working Mode 

10 seconds 

Double Flash 

Sleep Mode 

10 seconds 

Double Flash 

 
Please replace the batteries when the blink interval is 10 seconds! 

Summary of Contents for TI-700

Page 1: ...MODEL TI 700 Digital Weight Indicator with wireless weighing capability User Manual Revision 3 0 July 31 2017...

Page 2: ...the batteries TI 500 RFTM 5 Optional Rechargeable battery information 5 Balance of this page intentionally left blank 6 DISPLAY KEYPAD DETAILS 7 ADVANCED OPERATION 9 Hold operation 9 NET Weighing 9 Pi...

Page 3: ...UIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS Servicing of the equipment must only be carried out by trained and authorized personnel Use only the AC adapter supplied with the scale Other adapters m...

Page 4: ...old with an external TI 500 RFTM Radio Frequency Transceiver Module and an op tional wireless radio your TI 700 indicator is transformed from wired to cable free This config uration is depicted in the...

Page 5: ...sure press the UNITS key repeatedly un til it is indicated e g lb for pounds kg for kilograms etc The indicator features an automatic zero correction meaning that small deviations will be zeroed autom...

Page 6: ...he indicator for the first time please charge the battery overnight The indicator s battery should operate for about 85 hours if left on continuously The display unit is configured to power down after...

Page 7: ...th a pre installed power connector and an external battery charger Simply link the two up and plug the battery charger into a suitable AC wall outlet Note that the external battery charger is rated fo...

Page 8: ...P Indicates that the indicator is in PEAK HOLD mode lb Indicates that the unit of the displayed weight is in pounds kg Indicates that the unit of the displayed weight is in kilograms g Indicates that...

Page 9: ...Tare weight has been established first Tare This key is used to establish a Tare weight provided the following conditions are met 1 The indicator is displaying a Gross weight above zero 2 The scale i...

Page 10: ...values only PEAK HOLD F35 3 The display updates as the load increases but not as the load de creases The value shown on the screen is the maximum weight applied to the scale Press the UNITS key to tog...

Page 11: ...rs Available choices are 5 10 20 50 and 100 If you continue to push the UNITS key the indicator will resort back to weighing mode and you must start again from Step 2 3 Place the sample items on the p...

Page 12: ...e The system needs to be returned to the net zero range before another weight can be added 6 The subtotal can be checked by pressing the ON PRINT key for 3 seconds The display shows the net total weig...

Page 13: ...digit by pressing the UNITS key Decrease the flashing digit by pressing the ZERO OFF key Pressing the TARE key or the ON PRINT key will change the position of the flashing digit 10 After entering the...

Page 14: ...ht value with one digit blinking The pointer for SP1 is lit 2 Use the four directional keys to adjust the displayed value to the desired low weight value Increase the flashing digit by pressing the UN...

Page 15: ...SP1 light is ON Backlight colors is BLUE If the displayed weight net or gross is more than the High Max value then Digital Output 3 is activated SP3 light is ON Backlight colors is RED If the displaye...

Page 16: ...ndicator WIRELESS SYSTEMS ONLY TI 500 RFTM 1 batteries have been depleted and need to be replaced WIRELESS SYSTEMS ONLY TI 500 RFTM 2 batteries have been depleted and need to be replaced WIRELESS SYST...

Page 17: ...ight Operating temperature 4 F to 104 F 20 C to 40 C Internal connection port for optional printer Tilt adjustable bracket included AC Power 90 308 VAC 50 60 Hz DC Power 5 15 VDC OPTIONAL Bluetooth Sp...

Page 18: ...d cell damaged on platform Internal fault with indicator call Transcell Tech Support Scale turns off on its own The indicator has a power conservation feature set to automatically power off the scale...