![Trans-Cal SSD120-A-RS Series Owners & Installation Manual Download Page 13](http://html1.mh-extra.com/html/trans-cal/ssd120-a-rs-series/ssd120-a-rs-series_owners-and-installation-manual_1150596013.webp)
-13-
4.3 Required Equipment Dynamic Calibration
(See dynamic calibration block diagram.)
1. Primary flight altimeter or NIST traceable pressure standard.
2. +12 to 28VDC power supply.
3. IBM compatible computer with an available serial port.
4. Software requirement:
Windows 98
7
using
Hyper Terminal
Ver. 5.0 by
Hilgraeve. (Available as a free download at
http://www.hilgraeve.com
)
(Software Note: The
Hyper Terminal
program which is shipped with
Windows 98
7
will not function correctly. You must download
Version 5.0
or
better, to calibrate this device.)
5. A pitot-static test set, capable of exercising the altimeter and digitizer over a
range of -1000 feet to the maximum altitude of the digitizer.
6.
Optional
: ATS-200 or equal device which will allow the display of the 100
foot resolution parallel altitude data.