Trans Air EC3.0 Service Manual Download Page 3

EC3 Service Manual Jan. 8, 2008

3

10

Ground

11

Evaporator power return

12

Evaporator power input

Table 4 LED List

INDICATOR

FUNCTION

D25

Comp.

Illuminates when compressor relay is engaged.

D26

Cond.

Illuminates when condenser is engaged

D27

Tie-in comp.

Illuminates when tie-in compressor relay is engaged

D28

Tie-in cond.

Illuminates when tie-in condenser is engaged

D29

Heat

Illuminates when heat relay is engaged

D30

Com.

Illuminates and flickers

when board is powered up

D31

Evap.

Illuminates when evaporator is on

System Operation

Basic system operations are covered by the instruction manual (701465).

Thermostat Control Logic:

Temperature sensing

EC3.0 system has two thermistor type temperature sensors: cabin (internal) air temperature
sensor and ambient (external) air temperature sensor. The cabin air temperature sensor is
mounted in front of the main evaporator return air filter and the external temperature is
mounted externally but the location varies depending on vehicle models.
The electric resistance of the temperature sensor changes with the temperature. The sensing
circuit on the relay board can read the resistance and convert it to temperature reading. The
resistance of the temperature sensor is about 500 ohms at 70ºF. This can be uses as a
reference to determine if a temperature sensor is functional.
EC3.0 system only displays the temperature between 60 ºF and 90 ºF. If the actual
temperature is lower than 60 ºF, the display will show “Lo”. If the temperature is above
90ºF, the display will show “Hi”. The setpoint range is also set to be 60 ºF to 90 ºF.

Thermostat control logic

The compressor clutch, condenser and heat output are controlled by the thermostat based on
the temperature differential between cabin air temperature, Tin, and set point temperature,
Tset. The control logics are listed in Table 5.

Table 5 Thermostat control logic

MODE

CONTORLLED
COMPONENT

LOGIC

COOL

Clutch,

condenser

Tin>Tset+2 clutch & condenser turn on
Tin

Tset+2 clutch & condenser turn off

HEAT

Heat relay

Tin<Tset-3 heat relay engage
Tin

Tset+1 heat relay disengage

DEFOG

Heat relay

Clutch & condenser stay on
Heat relay regulate same as in heat mode