Trans Air EC3.0 Service Manual Download Page 1

EC3 Service Manual Jan. 8, 2008

1

Service Manual For

Trans/Air EC3.0 Electronic Climate Control System

Specification

Operating Voltage:

9~16 VDC

Current capacity:

Evaporator: 40 amp
Condenser: 40 amp
Compressor: 10 amp
Tie-in Condenser: 40 amp
Tie-in Compressor: 10 amp
Heat Relay:

10 amp

Setpoint range:

60ºF ~ 90ºF

Component:

EC3.0 system consist of two major components: driver control switches and relay board. A
communication cable connects the switches to the board.

Switches

EC3.0 control switches: Mode switch (701426), Thermostat (701425).

ON/OF & MODE SELECT
A/C-DEFOG-HEAT-OFF

FAN SPEED INDICATOR

FAN SPEED SELECT

AUTO-L-M-H-OFF

A/C

DEFOG

HEAT

SET POINT

ADJUST

DISPLAY

Figure 1 Control Switches

Relay Board

The layout of an EC3.0 relay board is shown below. It has five relays, one 12 position
terminal block, three 10 amp fuses, two connectors and seven LED indicators. The function
of each component are listed in table below