22-1825-09 5

General 

Data

AHRI Standard Capacity Rating Conditions

AHRI STANDARD 210/240 RATING CONDITIONS 

(A)  Cooling 80°F DB, 67°F WB air entering indoor coil, 

95°F DB air entering outdoor coil.

(B)  High Temperature Heating 47°F DB, 43°F WB air entering 

outdoor coil, 70°F DB air entering indoor coil.

(C) Low Temperature Heating 17°F DB, 15°F WB air entering 

outdoor coil, 70°F DB air entering indoor coil.

(D) Rated indoor airflow for heating is the same as for cooling. 
AHRI STANDARD 270 RATING CONDITIONS — (Noise 

rating numbers are determined with the unit in cooling opera-

tion.)  Standard Noise Rating number is at 95°F outdoor air.

Accessory Description and Usage

24 Volt Wiring Harness — Used to wire a communicating 

outdoor unit to an existing 24 Volt indoor section.
Charge Assist™ Solenoid Kit — fast/accurate charging 

every time.

Rubber Isolators

 — 5 large rubber donuts to isolate con-

densing unit from transmitting energy into mounting frame or 

pad. Use on any application where sound transmission needs 

to be minimized.

Extreme Condition Mount Kit

 — Bracket kits to securely 

mount condensing unit to a frame or pad without removing 

any panels. Use in areas with high winds, or on commercial 

roof tops, etc.

Low Ambient Cooling

 — For low ambient cooling below 55° 

see Application Guide SSC-APG005-EN.

Summary of Contents for XL20i 4TTZ0024A1

Page 1: ...XL20i 4TTZ0024 036 048 060 with ComfortLink II and Charge Assist 2 3 4 5 Tons Split System Cooling Product Data PUB NO 22 1825 09 ...

Page 2: ...nly two wire control connection CHARGE ASSIST fast accurate charging every time Glossy corrosion resistant finish Internal compressor high low pressure temperature protection Start kit standard 50 or 100 capacity modulation Compressor sump heat Electronic compressor control Liquid line filter drier Tarpaulin gray cabinet with anthracite gray top Low sound with advanced fan system and compressor so...

Page 3: ...s 2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 5 ARI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specification Options 11 ...

Page 4: ... Condition Mounting Kit BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 24 Volt Wiring Harness BAYACHP024A BAYACHP024A BAYACHP024A BAYACHP024A Refrigerant Lineset 5 TAYREFLN7 TAYREFLN7 TAYREFLN3 TAYREFLN3 1 Certified in accordance with the Air Source Unitar...

Page 5: ...he unit in cooling opera tion Standard Noise Rating number is at 95 F outdoor air Accessory Description and Usage 24 Volt Wiring Harness Used to wire a communicating outdoor unit to an existing 24 Volt indoor section Charge Assist Solenoid Kit fast accurate charging every time Rubber Isolators 5 large rubber donuts to isolate con densing unit from transmitting energy into mounting frame or pad Use...

Page 6: ...ctronic Filter Draft Inducer Speeds 1 Single Speed 2 Two Speed V Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A Brand T Better G Good Product Type A Air Handler Product Tier 2 Good Entry Level Feature Set 4 Better Retail Replacement Mid Effy 5 Better Entry Level High Effy Multi Speed 7 Best Retail Replacement High Effy Variable Speed 8 Best Retail Ultimate High Effy Variable Speed Major...

Page 7: ...22 1825 09 7 4TTZ0024 4TTZ0036 4TTZ0048 4TTZ0060 Electrical Data Schematic Diagrams SEE LEGEND ...

Page 8: ...8 22 1825 09 Electrical Data Schematic Diagrams SEE LEGEND Printed from D155834P01 Rev 00 4TTZ0024 4TTZ0036 4TTZ0048 4TTZ0060 ...

Page 9: ...22 1825 09 9 LEGEND SYMBOLS Schematic Diagrams Electrical Data ...

Page 10: ... dimensions are in MM Inches MODELS BASE A B C D E F G H J K 4TTZ0024A 4 1369 53 7 8 946 37 1 4 870 34 1 4 5 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 1035 40 3 4 4TTZ0036B 4TTZ0048B 4TTZ0060A 4 1369 53 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 1035 40 3 4 ...

Page 11: ...t on all other panels Corrosion and weather proof CMBP G30 DuraTuff base Refrigerant Controls Refrigeration system controls include condenser fan compressor contactor and high and low pressure switches High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor Two Climatuff compressors deliver 50 or 100 capacity modulation and feature...

Page 12: ...Trane www trane com 04 12 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice ...

Reviews: