Trane TWK509JB Installation Manual Download Page 2

General Information

MCW - SVN13A - E4

Foreword

These Installation instructions are
given as a guide to good practice in
the installation, start-up and operation
by the installers of MCW/MWW and
TTK/TWK mini-split systems.
They do not contain the full service
procedures necessary for the
continued successful operation of this
equipment. The services of a qualified
service technician should be
employed, through the medium of a
m a i n t e n a n c e   c o n t r a c t   w i t h   a
reputable service company.
Read them completely before doing
anything with your air conditioning
system.

Warranty

Warranty is based on the general
terms and conditions of the con-
structor. The warranty is void if the
equipment is modified or repaired
without the written approval of the
constructor, if the operating limits are
exceeded, or if the control system or
the electrical wiring is modified.
Damage due to misuse, lack of main-
tenance, or failure to comply with the
manufacturer

’s i

nstructions, is not

covered by the warranty obligation.
If the user does not conform to the
rules described in the manual, it may
entail cancellation of warranty and
liabilities by the Trane company.

Reception

On arrival, inspect the unit before
signing the delivery note. Specify any
damage on the delivery note, and
send a registered letter of protest to
the last carrier of the goods within 72
hours of delivery. Notify the local sales
office at the same time. The unit
should be totally inspected within 7
days of delivery. If any concealed
damage is discovered, send a
registered letter of protest to the
carrier within 7 days of delivery and
notify the local sales office. Units are
shipped with the refrigerant operating
or holding charge and should be
examined with an eletronic leak
detector to determine the hermetic
integrity of the unit. The refrigerant
charge is not included in the standard
Warranty Cover.

About this manual

Cautions appear at appropriate places
in this instruction manual Your
personal safety and the proper
operation of this machine require that
you follow them carefully. The con-
structor assumes no liability for
installations or servicing performed by
unqualified personnel.
All phases of the installation of these
air conditioning systems must
conformto all provinced/state and
local codes.
Please keep this installation manual
carefully for consultation.

About the unit

These MCW/MWW and TTK/TWK
units are assembled, pressure
tested, dehydrated, charged and run
t e s t e d   b e f o r e   s h i p m e n t .   T h e
infomation contained in this manual
applies to units designated MCW/
MWW and TTK/TWK. MCW and TTK
units are designed to operate in
cooling mode only, whereas MWW
and TWK can operate in cooling or
heating modes.

Refrigerant

The refrigerant provided by the con-
structor meets all the requirements
of our units. When using recycled or
reprocessed refrigerant, it is
advisable to ensure its quality is
equivalent to that of a new refrigerant.
For this, it is necessary to have a
p r e c i s e   a n a l y s i s   m a d e   b y   a
specialized laboratory. If this
condition is not respected, the
constructor warranty could be
cancelled.

Important

These instructions do not cover all
variations in system, nor do they
provide for every possible contin-
gency to be met.
Should further information be desired
or should particular problems arise
which are not covered sufficiently for
the purchaser

s purposes, the matter

should be referred to the Trane sales
office in your region.

c American Standard Inc. 2004

Summary of Contents for TWK509JB

Page 1: ...Hi Wall Type 9000 30000 Btu h 50Hz R22 September 2005 MCW SVN13A E4 Indoor Unit MWW509IB MWW512IB MWW518IB MWW524IB MWW526IB MWW530IB Outdoor Unit TWK509JB TWK512JB TWK518JB TWK524JB TWK526JB TWK530J...

Page 2: ...are shipped with the refrigerant operating or holding charge and should be examined with an eletronic leak detector to determine the hermetic integrity of the unit The refrigerant charge is not inclu...

Page 3: ...lation Location Installation for MWW509IB TWK509JB MWW512IB TWK512JB Installation for MWW518IB TWK518JB MWW524IB TWK524JB Installation for MWW526IB TWK526JB Installation for MWW530IB TWK530JB Pipe Ins...

Page 4: ...DB WB o C Outdoor Side DB WB o C Maximum Cooling 32 23 43 26 T1 Minimum Cooling 21 15 21 Maximum Heating 27 24 18 Minimum Heating 20 5 6 2 Sound Pressure level 1m from the unit It is sound data at hi...

Page 5: ...Mounting plate Wireless remote controller Battery Power connection cord Control cord Tapping screw Plastics drain hose Gum type sealer Thermal insulation hose Outdoor drain elbow Outdoor drain stem A...

Page 6: ...rvice personnel with reliability according to this manual Grounding wire should be connected with the special device If not please install it by profes sional personnel When lifting up and mov ing the...

Page 7: ...ct location where is easy to remove and clean the air filters 1 Select a location from which noise and air discharge by unit will not annoy neighbors 2 Select location where there should be sufficient...

Page 8: ...of an adult of 60kg furthermore the weight should be evenly shared by each screw Install the drain hose 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend...

Page 9: ...l 7 Recover the front panel Install the indoor unit 1 Thepipingroutingoftheindoor unitsee Figure 6 a b when routing the piping and wiring from the left or right side of the indoor unit cut off the tai...

Page 10: ...screws to the wiring terminal board Be sure that the wiring connection is in accordance with the indoor unit s 3 Fix the wiring with wire clamp joint the relevant interfaces accordingly 4 Make sure th...

Page 11: ...e should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water Figure 3 3 Lengthened drain hose should be wrapped with insulation when going through the room I...

Page 12: ...l piping hole Figure 6 3 Hang the grip at the back of the indoor unit to the hook on the mounting plate check if it is firm enough CAUTION 4 The height of the installation location should be more than...

Page 13: ...wrench refer to figure 7 Note Too large torque will damage the nut Tightening torque table Electric wire Connection 1 Remove the front right side panel of the outdoor unit and knock through the outdo...

Page 14: ...e 1 Cut the piping hole 1 Make the piping hole I65 in the wall at a slight downward slant to the outdoor side The center of the hole should be determined refer to Figure 1 2 Insert the piping hole sle...

Page 15: ...ing hole Figure 5 3 Hang the grip at the back of the indoor unit to the hook on the mounting plate check if it is firm enough 4 The height of the installation location should be more than 2 3m from th...

Page 16: ...Connection 1 Remove the front right side panel of the outdoor unit and knock through the outdoor wire hole Put on the wiring rubber ring 2 Remove the wire clamp and connect the end of the power conne...

Page 17: ...g hole 1 Make the piping hole I65 in the wall at a slight downward slant to the outdoor side The center of the hole should be determined refer to Figure 1 2 Insert the piping hole sleeve into the hole...

Page 18: ...3 Hang the grip at the back of the indoor unit to the hook on the mounting plate check if it is firm enough 4 The height of the installation location should be more than 2 3m from the floor Figure 4...

Page 19: ...ove the front right side panel of the outdoor unit and knock through the outdoor wire hole Put on the wiring rubber ring 2 Remove the wire clamp and connect the end of the power connection cord with s...

Page 20: ...edure Flaring work Pipe Installation Pipe cutting Cut the copper pipe correctly with pipe cutter Burrs removal Completely remove all burrs from the cut cross section of the pipe Put the end of the cop...

Page 21: ...door unit connection 1 2 Connect both liquid pipe and gas pipe to indoor unit Apply a thin coat of refrigeration oil to the seat surface of pipe For connection align the center of both pipe and union...

Page 22: ...used as a guideline The actual ones are up to the real situation at the job site and futher information can be found in Trane Application Mannual This information is for Trane Minisplit only Since Th...

Page 23: ...s stop pushing the valve core as soon as the refrigerantstartstobedischarged and reinstall the service port nut 8 Opentheliquidvalveandgasvalve entirely shown in Figure 14 9 Tighten the valve caps and...

Page 24: ...an be drained out fluently through the drain hose Installation Install the outdoor drain elbow in the 25 hole on the base plate as shown in Figure 16 and joint the drain hose to the elbow so that the...

Page 25: ...ause electric mal function or damage the part The refrigerant capacity is not accurate Situation 2 Test operation method 1 Switch on power and press 1 0 button on the remote controll 2 Press MODE butt...

Page 26: ...For MWW509IB TWK509JB MWW512IB TWK512JB Wiring Diagram For MWW518IB TWK518JB MCW SVN13A E4 26...

Page 27: ...For MWW524IB TWK524JB Wiring Diagram For MWW526IB TWK526JB MCW SVN13A E4 27...

Page 28: ...MCW SVN13A E4 28 For MWW530IB TWK530JB Wiring Diagram...

Page 29: ...g too slow Set the fan speed high or medium The heat insulation of refrigeran tube between outdoor indoor units is not good Breaker trips off or fuse blows When the breaker is set to on it trips off i...

Page 30: ...ime the constructor has at your disposal a refrigeration and air conditioning service school The principal aim of this is to give operators and maintenance tech nicians a better konwledge of the equip...

Reviews: