Trane TWG018A140C Installer'S Manual Download Page 4

4

18-GJ03D1-2

Installer’s Guide

WHEN FIELD-INSTALLED HEATERS ARE
 USED,  DISCARD POWER LEADS WITH 
POLARIZED PLUG 1-PM AND CONNECT
1-PF TO MATING PLUG IN THE HEATER 
CONTROL BOX AS SHOWN.

PRESSURE DROP FOR ELECTRIC HEATERS IN AIR HANDLER

MODELS

HEATER RACKS

HEATER

MODEL NO.

NO. OF

RACKS

BAYHTR1405

1

BAYHTR1408

2

BAYHTR1410
BAYHTR3410

2

BAYHTR1415
BAYHTR3415

3

If an electric heater is not installed, connections are made through the
7/8" knockout on the outside of the air handler, into the air handler to
the two power leads and ground wire connections which are located
near the discharge of the blower.

NOTE: If air handler is used with or  without a heater, the 7/8"
electrical entry hole as well as any other cabinet penetrations
must be sealed air tight.

Strip heater pressure
drop measurements
listed in this table must
be added to system
static pressure to
correctly use the corre-
sponding air flow
(blower) performance
tables located on page 5.

H.CONTROL WIRING

1. Connect wiring between indoor unit, outdoor unit and thermostat.

The use of color-coded low-voltage wires is recommended.

2. Field wiring diagrams are provided which show the low voltage

wiring hookup for a single speed cooling only system (with
supplementary heaters) and a heat pump system (with supple-
mentary heaters). Plug in type electrical connectors are provided
for use with supplementary heaters.

IMPORTANT: When supplementary heaters are installed, inspect
to insure that all packaging material has been removed.

NOTE: Direct drive motors have bearings which are permanently
lubricated and under normal use lubrication is not
recommended.

4"

6"

17"

1"

3/8"

1/4" HOLES (4)

ACCESSORY BAY99X123

IF AIRHANDLER IS USED 

WITHOUT

 A FACTORY FURNISHED

SUPPLEMENTARY HEATER, A PLATE IS REQUIRED TO COVER
THE OPEN HOLE IN THE AIR FLOW SYSTEM

Figure 5. Heater Plate - Order Accessory BAY99X123 or field

fabricate to these dimensions

From Dwg. No. B801083

TWG AIR HANDLERS WITH SINGLE STAGE COOLING, 1 STAGE

HEAT

WHEN FIELD-INSTALLED HEATERS ARE
 USED,  DISCARD POWER LEADS WITH 
POLARIZED PLUG 1-PM AND CONNECT
1-PF TO MATING PLUG IN THE HEATER 
CONTROL BOX AS SHOWN.

TWG AIR HANDLERS WITH SINGLE SPEED HEAT PUMP

From Dwg. No. B801082

WHEN FIELD-INSTALLED HEATERS ARE
 USED,  DISCARD POWER LEADS WITH 
POLARIZED PLUG 1-PM AND CONNECT
1-PF TO MATING PLUG IN THE HEATER 
CONTROL BOX AS SHOWN.

From Dwg. No. B801081

TWG AIR HANDLERS WITH SINGLE STAGE COOLING AND

TWO STAGE HEATING

Summary of Contents for TWG018A140C

Page 1: ...idered 1 If adequate power is available and correct according to name plate specifications 2 Insulate and seal all ducts particularly if unit is located outside of the conditioned space 3 To ensure ma...

Page 2: ...is shipped from the factory in the horizontal left airflow position 3 Openings where field wiring enters the cabinet must be completely sealed Location of power entry is shown on the Outline Drawing...

Page 3: ...drain outlet connection 3 It is recommended that a clean out tee or cross be installed in the primary drain line for future maintenance See Figure 4 4 Do not use reducing fittings in the condensate dr...

Page 4: ...grams are provided which show the low voltage wiring hookup for a single speed cooling only system with supplementary heaters and a heat pump system with supple mentary heaters Plug in type electrical...

Page 5: ...ERNAL STATIC PRESSURE INCHES OF WATER VERTICAL See Notes HORIZONTAL See Notes 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS CFM HI MED LO HI MED LO HI MED LO HI MED LO 850 0 59 900 0 55 0 54 0 65 0 49 0 38...

Page 6: ...6 18 GJ03D1 2 Installer s Guide OUTLINE DRAWING FOR TWG018 036A140C D810094REV05...

Page 7: ...18 GJ03D1 2 7 Installer s Guide OUTLINE DRAWING FOR TWG037 042 048 060A D810126REV04...

Page 8: ...pleted it is recommended that the Air Handler be checked against the following checklist 1 Operational Procedure for the system installation can be found in the outdoor unit installer guide and will b...

Reviews: