background image

©2022

SSP-SVX001D-EN

Introduction

Read this manual thoroughly before operating or
servicing this unit.

Warnings, Cautions, and Notices

Safety advisories appear throughout this manual as
required. Your personal safety and the proper
operation of this machine depend upon the strict
observance of these precautions.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.

CAUTION

Indicates a potentially hazardous situation
which, if not avoided, could result in minor or
moderate injury. It could also be used to alert
against unsafe practices.

NOTICE

Indicates a situation that could result in
equipment or property-damage only
accidents.

Important Environmental Concerns

Scientific research has shown that certain man-made
chemicals can affect the earth’s naturally occurring
stratospheric ozone layer when released to the
atmosphere. In particular, several of the identified
chemicals that may affect the ozone layer are
refrigerants that contain Chlorine, Fluorine and Carbon
(CFCs) and those containing Hydrogen, Chlorine,
Fluorine and Carbon (HCFCs). Not all refrigerants
containing these compounds have the same potential
impact to the environment. Trane advocates the
responsible handling of all refrigerants-including
industry replacements for CFCs and HCFCs such as
saturated or unsaturated HFCs and HCFCs.

Important Responsible Refrigerant
Practices

Trane believes that responsible refrigerant practices
are important to the environment, our customers, and
the air conditioning industry. All technicians who
handle refrigerants must be certified according to local
rules. For the USA, the Federal Clean Air Act (Section
608) sets forth the requirements for handling,
reclaiming, recovering and recycling of certain
refrigerants and the equipment that is used in these
service procedures. In addition, some states or
municipalities may have additional requirements that
must also be adhered to for responsible management
of refrigerants. Know the applicable laws and follow
them.

W

WA

AR

RN

NIIN

NG

G

P

Prro

op

pe

err F

Fiie

elld

d W

Wiirriin

ng

g a

an

nd

d G

Grro

ou

un

nd

diin

ng

g

R

Re

eq

qu

uiirre

ed

d!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w cco

od

de

e cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr

sse

erriio

ou

uss iin

njju

urry

y..

A

Allll ffiie

elld

d w

wiirriin

ng

g M

MU

US

ST

T b

be

e p

pe

errffo

orrm

me

ed

d b

by

y q

qu

ua

alliiffiie

ed

d

p

pe

errsso

on

nn

ne

ell.. IIm

mp

prro

op

pe

errlly

y iin

nsstta

alllle

ed

d a

an

nd

d g

grro

ou

un

nd

de

ed

d

ffiie

elld

d w

wiirriin

ng

g p

po

osse

ess F

FIIR

RE

E a

an

nd

d E

EL

LE

EC

CT

TR

RO

OC

CU

UT

TIIO

ON

N

h

ha

azza

arrd

dss.. T

To

o a

av

vo

oiid

d tth

he

esse

e h

ha

azza

arrd

dss,, y

yo

ou

u M

MU

US

ST

T ffo

ollllo

ow

w

rre

eq

qu

uiirre

em

me

en

nttss ffo

orr ffiie

elld

d w

wiirriin

ng

g iin

nsstta

alllla

attiio

on

n a

an

nd

d

g

grro

ou

un

nd

diin

ng

g a

ass d

de

essccrriib

be

ed

d iin

n N

NE

EC

C a

an

nd

d y

yo

ou

urr llo

occa

all//

sstta

atte

e//n

na

attiio

on

na

all e

elle

eccttrriicca

all cco

od

de

ess..

W

WA

AR

RN

NIIN

NG

G

P

Pe

errsso

on

na

all P

Prro

otte

eccttiiv

ve

e E

Eq

qu

uiip

pm

me

en

ntt ((P

PP

PE

E))

R

Re

eq

qu

uiirre

ed

d!!

F

Fa

aiillu

urre

e tto

o w

we

ea

arr p

prro

op

pe

err P

PP

PE

E ffo

orr tth

he

e jjo

ob

b b

be

eiin

ng

g

u

un

nd

de

errtta

akke

en

n cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr sse

erriio

ou

uss iin

njju

urry

y..

T

Te

ecch

hn

niicciia

an

nss,, iin

n o

orrd

de

err tto

o p

prro

otte

ecctt tth

he

em

msse

ellv

ve

ess ffrro

om

m

p

po

otte

en

nttiia

all e

elle

eccttrriicca

all,, m

me

ecch

ha

an

niicca

all,, a

an

nd

d cch

he

em

miicca

all

h

ha

azza

arrd

dss,, M

MU

US

ST

T ffo

ollllo

ow

w p

prre

ecca

au

uttiio

on

nss iin

n tth

hiiss m

ma

an

nu

ua

all

a

an

nd

d o

on

n tth

he

e tta

ag

gss,, ssttiicckke

errss,, a

an

nd

d lla

ab

be

ellss,, a

ass w

we

ellll a

ass tth

he

e

iin

nssttrru

uccttiio

on

nss b

be

ello

ow

w::

••

B

Be

effo

orre

e iin

nsstta

alllliin

ng

g//sse

errv

viicciin

ng

g tth

hiiss u

un

niitt,,

tte

ecch

hn

niicciia

an

nss M

MU

US

ST

T p

pu

utt o

on

n a

allll P

PP

PE

E rre

eq

qu

uiirre

ed

d ffo

orr

tth

he

e w

wo

orrkk b

be

eiin

ng

g u

un

nd

de

errtta

akke

en

n ((E

Ex

xa

am

mp

plle

ess;; ccu

utt

rre

essiisstta

an

ntt g

gllo

ov

ve

ess//sslle

ee

ev

ve

ess,, b

bu

utty

yll g

gllo

ov

ve

ess,, ssa

affe

etty

y

g

glla

asssse

ess,, h

ha

arrd

d h

ha

att//b

bu

um

mp

p cca

ap

p,, ffa

allll p

prro

otte

eccttiio

on

n,,

e

elle

eccttrriicca

all P

PP

PE

E a

an

nd

d a

arrcc fflla

assh

h ccllo

otth

hiin

ng

g))..

A

AL

LW

WA

AY

YS

S rre

effe

err tto

o a

ap

pp

prro

op

prriia

atte

e S

Sa

affe

etty

y D

Da

atta

a

S

Sh

he

ee

ettss ((S

SD

DS

S)) a

an

nd

d O

OS

SH

HA

A g

gu

uiid

de

elliin

ne

ess ffo

orr

p

prro

op

pe

err P

PP

PE

E..

••

W

Wh

he

en

n w

wo

orrkkiin

ng

g w

wiitth

h o

orr a

arro

ou

un

nd

d h

ha

azza

arrd

do

ou

uss

cch

he

em

miicca

allss,, A

AL

LW

WA

AY

YS

S rre

effe

err tto

o tth

he

e a

ap

pp

prro

op

prriia

atte

e

S

SD

DS

S a

an

nd

d O

OS

SH

HA

A//G

GH

HS

S ((G

Gllo

ob

ba

all H

Ha

arrm

mo

on

niizze

ed

d

S

Sy

ysstte

em

m o

off C

Clla

assssiiffiicca

attiio

on

n a

an

nd

d L

La

ab

be

elllliin

ng

g o

off

C

Ch

he

em

miicca

allss)) g

gu

uiid

de

elliin

ne

ess ffo

orr iin

nffo

orrm

ma

attiio

on

n o

on

n

a

allllo

ow

wa

ab

blle

e p

pe

errsso

on

na

all e

ex

xp

po

ossu

urre

e lle

ev

ve

ellss,, p

prro

op

pe

err

rre

essp

piirra

atto

orry

y p

prro

otte

eccttiio

on

n a

an

nd

d h

ha

an

nd

dlliin

ng

g

iin

nssttrru

uccttiio

on

nss..

••

IIff tth

he

erre

e iiss a

a rriisskk o

off e

en

ne

errg

giizze

ed

d e

elle

eccttrriicca

all

cco

on

ntta

acctt,, a

arrcc,, o

orr fflla

assh

h,, tte

ecch

hn

niicciia

an

nss M

MU

US

ST

T p

pu

utt

o

on

n a

allll P

PP

PE

E iin

n a

acccco

orrd

da

an

ncce

e w

wiitth

h O

OS

SH

HA

A,, N

NF

FP

PA

A

7

70

0E

E,, o

orr o

otth

he

err cco

ou

un

nttrry

y--ssp

pe

ecciiffiicc rre

eq

qu

uiirre

em

me

en

nttss

ffo

orr a

arrcc fflla

assh

h p

prro

otte

eccttiio

on

n,, P

PR

RIIO

OR

R tto

o sse

errv

viicciin

ng

g

tth

he

e u

un

niitt.. N

NE

EV

VE

ER

R P

PE

ER

RF

FO

OR

RM

M A

AN

NY

Y S

SW

WIIT

TC

CH

HIIN

NG

G,,

D

DIIS

SC

CO

ON

NN

NE

EC

CT

TIIN

NG

G,, O

OR

R V

VO

OL

LT

TA

AG

GE

E T

TE

ES

ST

TIIN

NG

G

W

WIIT

TH

HO

OU

UT

T P

PR

RO

OP

PE

ER

R E

EL

LE

EC

CT

TR

RIIC

CA

AL

L P

PP

PE

E A

AN

ND

D

A

AR

RC

C F

FL

LA

AS

SH

H C

CL

LO

OT

TH

HIIN

NG

G.. E

EN

NS

SU

UR

RE

E

E

EL

LE

EC

CT

TR

RIIC

CA

AL

L M

ME

ET

TE

ER

RS

S A

AN

ND

D E

EQ

QU

UIIP

PM

ME

EN

NT

T A

AR

RE

E

P

PR

RO

OP

PE

ER

RL

LY

Y R

RA

AT

TE

ED

D F

FO

OR

R IIN

NT

TE

EN

ND

DE

ED

D

V

VO

OL

LT

TA

AG

GE

E..

Summary of Contents for TWA0724-A Series

Page 1: ...ing on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment March 2022 S SS SP P S SV VX X0 00 01 1D D E EN N Installation Ope...

Page 2: ...r r p pr ro op pe er r P PP PE E f fo or r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i i...

Page 3: ...u uc ct ti io on ns s b be el lo ow w c co ou ul ld d r re es su ul lt t i in n a an n e ex xp pl lo os si io on n w wh hi ic ch h c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se...

Page 4: ...ng and Isolating Refrigerant Lines 21 Refrigerant Charging Procedure 22 Charging Levels 23 Liquid Charging 24 Electrical Wiring 24 Unit Power Supply 25 Low Voltage Wiring 25 Symbio Controls 25 Field W...

Page 5: ...0Hz Digit 9 Refrigeration Circuit Stage A 1 Compressor 1 Line 1 Stage Single D 2 Compressors 2 Line 2 Stage Dual Digit 10 Major Design Sequence A Rev A B Rev B Digit 11 Minor Design Sequence A Rev A D...

Page 6: ...s step will void the unit s warranties Installation procedures should be performed in the sequence that they appear in this manual Do not destroy or remove the manual from the unit The manual should r...

Page 7: ...lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y a an nd d e eq qu ui ip pm me en nt t o or r p pr ro op pe er rt ty y o on nl ly y d da am ma ag ge e T Te es st t l li if f...

Page 8: ...see Weights p 16 The unit should be elevated on a level field fabricated four inch steel or wood 4 x 4 mounting frame Complete the frame and secure it into position before lifting the unit to the roof...

Page 9: ...tremes in temperature Performed initial leak test Evacuated each refrigerant circuit to 500 microns Charged each circuit with proper amount of R 410A R 22 Electrical Wiring Provided unit power wiring...

Page 10: ...in mm W in mm D in mm TWA0604DA 0724 A 0764DA 0904 A R 410A and TTA090 R 22 39 2 996 42 1 1070 36 3 922 TWA0604DD 0724 D 0764DD 0904 D R 410A 39 2 996 51 9 1317 39 3 999 TWA101 120 R 410A TWA120 R 22...

Page 11: ...ONTROL WIRING OPTIONAL LINE VOLTAGE CONTROL WIRING SUCTION LINE LIQUID LINE BOTTOM OF UNIT 7 16 11 11 DIA ISOLATOR MOUNTING HOLES OUTSIDE HOLES 4 PLACES SERVICE PANEL SIDE SEE NOTE 4 HAIL GUARD OPTION...

Page 12: ...S 4 PLACES SERVICE PANEL SIDE 50 7 8 1293 51 11 16 1312 WITH HAIL GUARD SEE NOTE 1 THIS HOLE FOR 7 5T ONLY REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL SERVICE CLEARANCE 48 1219 2 SEE NOTE 2 FOR C...

Page 13: ...NOTE 1 REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL SERVICE CLEARANCE 48 1219 2 SEE NOTE 2 FOR CLEARANCE HAIL GUARD OPTIONAL HAIL GUARD OPTIONAL NOTES 1 ACCESS OPENING IS FOR FIELD INSTALLED BAYL...

Page 14: ...IDE HOLES 4 PLACES SERVICE PANEL SIDE 50 7 8 1293 51 11 16 1312 WITH HAIL GUARD SEE NOTE 1 REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL SERVICE CLEARANCE 48 1219 2 SEE NOTE 2 FOR CLEARANCE HAIL GU...

Page 15: ...NEL SIDE BOTTOM OF UNIT SUCTION LINE REFRIGERANT GAUGE ACCESS LINE VOLTAGE LIQUID LINE CONTROL WIRING FRONT DETAIL A DIMENSIONAL DEATIL NOTES 1 MINIMUM CLEARANCE FOR PROPER OPERATION IS 36 914 4 FROM...

Page 16: ...ble 2 TWA R 22 unit and corner weights lbs 60 Hz Tons Model No Shipping Max lbs Net Max lbs Corner Weights 1 2 3 4 7 5 TWA0902 A 397 360 112 105 74 69 10 TWA1202 A 482 437 110 129 91 107 15 TWA1802 D...

Page 17: ...A072 090 120 TWA060 076 101 TWA0902 A 1202 A 1 2 3 4 LIFTING HOLES BOTH SIDES SERVICE ACCESS Figure 9 TWA180 240 TWA156 201 TWA1802 D TWA2402 D SERVICE ACCESS SERVICE ACCESS 1 2 3 4 LIFTING HOLES BOTH...

Page 18: ...ble elevation difference TTA or TWA below indoor unit Acceptable liquid riser height based on total liquid line length below indoor unit Contact manufacturer for review N No ot te e Route refrigerant...

Page 19: ...R Re ec co ov ve er r r re ef fr ri ig ge er ra an nt t t to o r re el li ie ev ve e p pr re es ss su ur re e b be ef fo or re e o op pe en ni in ng g t th he e s sy ys st te em m S Se ee e u un ni it...

Page 20: ...Un ni it t D Da am ma ag ge e D Do o n no ot t a ap pp pl ly y h he ea at t t to o r re em mo ov ve e s se ea al l c ca ap ps s u un nt ti il l t th he e g ga au ug ge e p po or rt t c co or re es s...

Page 21: ...e refrigerant charging hoses from liquid and gas gauge ports 9 Leak test the entire system Using proper procedures and caution as described in the previous section repair any leaks found and repeat th...

Page 22: ...e the balance of the unit charge can be metered through a charging manifold set as liquid preferably through a schrader valve into the suction line to the compressor only while the compressor is runni...

Page 23: ...04 B 11 8 11 8 0 5 1 2 1 125 1 1 8 TWA1014DA w TWE1014DA 27 3 N A 0 5 1 2 1 375 1 3 8 TWA1014DD w TWE1014DB 13 9 14 0 0 5 1 2 1 125 1 1 8 TWA1204 A w TWE1204 A 27 5 N A 0 5 1 2 1 375 1 3 8 TWA1204 D w...

Page 24: ...e d di is sc co on nn ne ec ct ts s a an nd d d di is sc ch ha ar rg ge e a al ll l m mo ot to or r s st ta ar rt t r ru un n c ca ap pa ac ci it to or rs s b be ef fo or re e s se er rv vi ic ci in n...

Page 25: ...Mount the indoor thermostat zone sensor or programmable zone sensor in accordance with the corresponding thermostat installation instructions Install color coded weather proof multi wire cable accordi...

Page 26: ...g Refer to the latest version of Condenser and Air Handler Pairing guide SS SVN016 EN for instructions on field wiring connections Refrigerant Circuit Figure 15 Typical split system heat pump cooling...

Page 27: ...ISCHARGE TEMPERATURE LIMIT DTL HIGH PRESSURE SWITCH HPCO DE ICE LOOP NOTE A CHECK VALVES 4 WAY SWITCHOVER VALVE LOW PRESSURE SWITCH LPCO EQUALIZER LINE NOTE A ONLY ONE OUTDOOR AND INDOOR COIL REFRIGER...

Page 28: ...ompressor and the outdoor fans if suction pressure drops below the Low Pressure Cut Out setting Once the suction pressure has returned to normal the compressor and outdoor fans will cycle back on High...

Page 29: ...y W Wh he en n i it t i is s n ne ec ce es ss sa ar ry y t to o w wo or rk k w wi it th h l li iv ve e e el le ec ct tr ri ic ca al l c co om mp po on ne en nt ts s h ha av ve e a a q qu ua al li if...

Page 30: ...mbio Service and Installation mobile application The modes shown below can be initiated Depending on the equipment configuration the controller will energize the appropriate outputs A user selected ti...

Page 31: ...ng maintenance inspections once per month Check unit wiring to ensure all connections are tight and that the wiring insulation is intact Inspect the condenser coils for dirt and debris If the coils ap...

Page 32: ...32 SSP SVX001D EN inadvertently bent during the cleaning process M Ma ai in nt te en na an nc ce e...

Page 33: ...or Superheat F at compressor Subcooling F at liquid line Dry Bulb Wet Bulb Suction Pressure Discharge Pressure Circuit 1 Circuit 2 Circuit 1 Circuit 2 C1 C2 C1 C2 Note Perform each inspection once per...

Page 34: ...04 A 436766050001 436766270001 TWA0764DD TWE0764DB 436759340001 436759670001 TWA0904 D TWE0904 B 436759350001 436759680001 TWA1014DA TWE1014DA 436766080001 436766340001 TWA1204 A TWE1204 A 43676609000...

Page 35: ...060 072 090 120 and Digit 9 A 1213 4183 Control Schematic Wiring Diagram for units with Dual compressor and Single Fan All TWA Units with Digit 4 6 060 072 076 090 and Digit 9 D 1213 4184 Control Sch...

Page 36: ...or shipments outside the conterminous United States a replacement product or at the option of the warrantor parts for the repair of the product not conforming to this warranty and which have been retu...

Page 37: ...SSP SVX001D EN 37 N No ot te es s...

Page 38: ...38 SSP SVX001D EN N No ot te es s...

Page 39: ...SSP SVX001D EN 39 N No ot te es s...

Page 40: ...se visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications wit...

Reviews: