Trane TTV Installation Operation & Maintenance Download Page 21

TTV-IOM-R410A

21

Dimensional Data

TTV 600

FAN ARRANGEMENT 3

FAN ARRANGEMENT 4

SIDE VIEW

REAR VIEW

20" X 25"

1777

1241 1275

COIL

REAR

TOP VIEW

TOP COIL

FILTER

FILTER

1725

461

571

741

851

FAN

MOTOR

2-1/8" SUCTION LINE

1-1/8" LIQUID LINE

1" DRAIN PIPE

FILTER

20" X 25"

20" X 20"

BOTTOM COIL

20" X 25"

1090.5

BOTTOM COIL

TOP COIL

20" X 25"

20" X 20"

20" X 25"

20" X 25"

20" X 25"

20" X 20"

20" X 25"

20" X 25"

FRONT

569

2562

2596

569

452

51

486

486

CLEARANCE

RECOMMENDED

750

CLEARANCE

RECOMMENDED

750

RECOMMENDED CLEARANCE

750

38 DIA. KNOCKOUT FOR
POWER SUPPLY AND CONTROL

SIDE VIEW

REAR VIEW

20" X 25"

1777

1241 1275

COIL

REAR

TOP VIEW

TOP COIL

FILTER

FILTER

1725

461

571

741

851

FAN

MOTOR

2-1/8" SUCTION 

1-1/8" LIQUID LINE

1" DRAIN PIPE

FILTER

20" X 25"

20" X 20"

BOTTOM COIL

20" X 25"

1090.5

BOTTOM COIL

TOP COIL

20" X 25"

20" X 20"

20" X 25"

20" X 25"

20" X 25"

20" X 20"

20" X 25"

20" X 25"

569

2562

2596

FRONT

569

452

30

486

486

CLEARANCE

RECOMMENDED

750

CLEARANCE

RECOMMENDED

750

RECOMMENDED CLEARANCE

750

38 DIA. KNOCKOUT FOR
POWER SUPPLY AND CONTROL

Summary of Contents for TTV

Page 1: ...s and requires specific knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe...

Page 2: ...ly Fan Motor kW 5 15 Supply Fan Motor kW Digit 11 Minor Design Sequence Digit 12 0 No Discharge Plenum A 1st Minor Design Sequence Digit 13 A Internal Filter Rack 1 Filter B External Filter Rack 2 Fil...

Page 3: ...TTV IOM R410A 3 Contents Model Nomenclature System Precaution General Information General Data Installation Operation Start Up Maintenance Dimensional Data Electrical Wiring 2 4 5 6 8 9 10 12 23...

Page 4: ...ing leakage of water etc Be sure to cut off the main power in case of setting up the indoor electronic control P C board or wiring works It could cause an electri shock Any presence of foreign substan...

Page 5: ...d mail Notify the local Trane Sales Office Concealed damage must be reported within 15 days delivery Check the unit nameplate to confirm that the proper unit was shipped Available power supply must be...

Page 6: ...6 TTV IOM R410A General Data TTV250 400...

Page 7: ...TTV IOM R410A 7 General Data TTV500 800...

Page 8: ...d on a sub base so that adequate height can be provided for a condensate drain trap However if adequate drainage can be provided the unit may be mounted directly on the floor It is recommended that ei...

Page 9: ...connections completed Wiring is correct and in accordance with the wiring diagram with all connections secure Ground connection completed Check and retighten if necessary set screws on the drive fan p...

Page 10: ...ondensate drain pan and condensate piping to make sure they are clear and will carry away all water 8 Inspect the control panel wiring to make sure connections are tight and insulation is intact Chang...

Page 11: ...is 2 5 Voltage imbalance is defined as the sum of the deviation of the three voltages from the average without regard to sign divided by twice the average voltage e g if the three measured voltages ar...

Page 12: ...RECOMMENDED 750 RECOMMENDED CLEARANCE 750 CLEARANCE RECOMMENDED 750 RECOMMENDED CLEARANCE 750 TOP VIEW SIDE VIEW 16 X 20 16 X 20 16 X 20 16 X 20 16 X 20 16 X 20 16 X 20 16 X 20 1219 13 1008 1040 COIL...

Page 13: ...ECOMMENDED CLEARANCE 750 CLEARANCE RECOMMENDED RECOMMENDED CLEARANCE 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL 750 REAR VIEW REAR FRONT SIDE VIEW 16 X 20 16 X 20 16 X 20 16 X 20 16 X 20 16 X 20 16...

Page 14: ...RECOMMENDED CLEARANCE RECOMMENDED 750 RECOMMENDED CLEARANCE 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL 750 TOP VIEW REAR VIEW REAR FRONT SIDE VIEW 16 X 20 16 X 20 16 X 25 15 X 25 15 X 20 15 X 20 137...

Page 15: ...EARANCE RECOMMENDED RECOMMENDED CLEARANCE 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL 750 COIL TOP VIEW REAR VIEW REAR FRONT SIDE VIEW 16 X 20 16 X 20 16 X 25 15 X 25 15 X 20 15 X 20 1372 13 1008 104...

Page 16: ...EARANCE RECOMMENDED 750 750 CLEARANCE RECOMMENDED RECOMMENDED CLEARANCE 750 RECOMMENDED CLEARANCE 750 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL SIDE VIEW REAR VIEW 20 X 25 16 X 25 1520 481 1008 104...

Page 17: ...46 361 361 67 CLEARANCE RECOMMENDED 750 750 CLEARANCE RECOMMENDED RECOMMENDED CLEARANCE 750 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL SIDE VIEW REAR VIEW 20 X 25 16 X 25 1520 1008 1040 COIL FRONT...

Page 18: ...ARANCE RECOMMENDED 750 750 CLEARANCE RECOMMENDED RECOMMENDED CLEARANCE 750 RECOMMENDED CLEARANCE 750 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL SIDE VIEW REAR VIEW 25 X 25 16 X 25 1653 569 1241 1275...

Page 19: ...ISOMETRIC VIEW CLEARANCE RECOMMENDED 750 750 CLEARANCE RECOMMENDED RECOMMENDED CLEARANCE 750 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL SIDE VIEW REAR VIEW 25 X 25 16 X 25 1653 1241 1275 COIL REAR...

Page 20: ...OMMENDED 750 CLEARANCE RECOMMENDED 750 RECOMMENDED CLEARANCE 750 RECOMMENDED CLEARANCE 750 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL SIDE VIEW REAR VIEW 20 X 25 1777 1241 1275 COIL REAR TOP VIEW TO...

Page 21: ...569 452 51 486 486 CLEARANCE RECOMMENDED 750 CLEARANCE RECOMMENDED 750 RECOMMENDED CLEARANCE 750 38 DIA KNOCKOUT FOR POWER SUPPLY AND CONTROL SIDE VIEW REAR VIEW 20 X 25 1777 1241 1275 COIL REAR TOP V...

Page 22: ...22 TTV IOM R410A Dimensional Data TTV 800 FAN ARRANGEMENT 1...

Page 23: ...T ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH USE COPPER CONDUCTORS ONLY TO PREVENT EQUIPMEN...

Page 24: ...ations without notice We are committed to using environmentally conscious print practices Trane by Trane Technologies NYSE TT a global climate innovator creates comfortable energy efficient indoor env...

Reviews: