19
Pub. No. 22-1840-14
TDHM AIRFLOW - COOLING
NOTE:
CONTINUOUS fan mode during COOLING operation
may not be appropriate in humid climates. If the
indoor air exceeds 60% relative humidity or simply
feels uncomfortably humid, it is recommended that
the fan only be used in the AUTO mode.
*DHMD120BCV5VB^
Furnace Cooling Airflow (CFM) & Power (Watts) vs. External Static Pressure w/Filter
0.1
0.3
0.5
0.7
0.9
CFM
1046
1103
1032
1027
1022
Watts
131
157
210
251
295
CFM
1111
1172
1102
1099
1095
Watts
153
180
237
280
326
CFM
1177
1242
1171
1171
1167
Watts
178
207
266
313
363
CFM
1242
1311
1240
1243
1240
Watts
205
236
300
350
404
CFM
1307
1381
1310
1315
1312
Watts
236
269
337
392
450
CFM
1405
1485
1414
1422
1421
Watts
289
325
401
464
531
CFM
1503
1589
1518
1530
1530
Watts
351
389
476
547
627
CFM
1569
1658
1587
1602
1603
Watts
397
436
533
610
700
CFM
1181
1247
1176
1176
1172
Watts
180
209
269
316
365
CFM
1256
1326
1255
1258
1255
Watts
212
243
308
359
413
CFM
1331
1405
1335
1340
1338
Watts
248
282
352
408
468
CFM
1405
1485
1414
1422
1421
Watts
289
325
401
464
531
CFM
1480
1564
1493
1505
1504
Watts
336
373
457
526
602
CFM
1592
1683
1612
1628
1629
Watts
415
454
554
634
728
CFM
1704
1802
1731
1751
1753
Watts
507
548
667
761
877
CFM
1778
1882
1810
1833
1836
Watts
577
617
753
857
991
CFM
1452
1534
1463
1474
1473
Watts
318
354
436
502
574
CFM
1545
1634
1562
1577
1577
Watts
380
419
512
587
673
CFM
1639
1733
1661
1679
1681
Watts
452
492
599
685
787
CFM
1732
1832
1760
1782
1784
Watts
533
573
699
796
918
CFM
1825
1931
1859
1885
1888
Watts
624
663
811
922
925
CFM
1965
2080
1977
1902
1853
Watts
781
925
925
925
925
CFM
2064
2229
1977
1902
1853
Watts
925
925
925
925
925
CFM
2064
2250
1977
1902
1853
Watts
925
925
925
925
925
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting;
NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
Cool
in
g
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
External Static Pressure
Airflow Setting
Unit Outdoor Size
(tons)
310 CFM/ton
330 CFM/ton
290 CFM/ton
290 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
3.5
4
5
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton