background image

Since 

Trane

 has a policy of continuous product and product data improvement, 

it

 reserves the right to 

change design and specifications without notice.

Trane

6200 Troup Highway
Tyler, TX 75707
www.trane.com

04/15

Summary of Contents for TDC1B040A9241A

Page 1: ...Downflow Horizontal Condensing Gas Fired Furnace XB 90 TDC1B040A9241A TDC1B060A9361A TDC1B080A9421A TDC1C100A9481A TDC1D120A9601A Single Stage Fan Assisted Combustion System PUB NO 22 1670 10 ...

Page 2: ... of furnace limit sensors blowers gas valve flame control and includes self diagnostics for ease of service Also contains connec tion points for E A C humidifier AIR DELIVERY The variable speed direct drive blower motor has sufficient airflow for most heating and cooling requirements will switch from heating to cooling speeds on demand from room thermostat The blower door safety switch will preven...

Page 3: ...ture Summary Features and Benefits Standard Equipment Optional Equipment General Data TDC1B040A9241A TDC1B060A9361A TDC1B080A9421A TDC1C100A9481A TDC1D120A9601A Performance Data Electrical Data Field Wiring Dimensions 2 4 6 8 9 11 13 ...

Page 4: ...Silicon Nitride hot surface igniter with adaptive heat up Accessory hook up capability Hum and EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve regulator PVC venting 1 Pipe Left right gas connection Selectable cooling fan off delay elimi nates need for BAY24X045 time delay relay Integrated solid state control with self diagnostics 24 volt fuse Manual res...

Page 5: ...Gas Furnace TFM175A9FR0 Electronic Air Filter Perfect Fit High Efficiency 21 Wide Gas Furnace TFM210A9FR0 Electronic Air Filter Perfect Fit High Efficiency 24 1 2 Wide Gas Furnace TFM245A9FR0 Electronic Air Filter Perfect Fit Standard Efficiency 17 1 2 Wide Gas Furnace TFP175A9FR0 Electronic Air Filter Perfect Fit Standard Efficiency 21 Wide Gas Furnace TFP210A9FR0 Electronic Air Filter Perfect Fi...

Page 6: ...MENSIONS Crated In WEIGHT Shipping Lbs Net Lbs PRODUCT SPECIFICATIONS 1 TDC1B040A9241A Downflow Horizontal 40 000 38 000 92 1 30 60 DIRECT 10 x 7 1 4 See Fan Performance Table 1 5 1080 115 1 60 Centrifugal Direct 1 1 55 3000 115 1 60 1 0 No High Velocity 2 14x20 1in 2 Round Aluminized Steel Type I 20 2 45 2 56 Redundant Single Stage Hot Surface Ignition Multiport Inshot 2 115 1 60 4 7 15 1 2 H x W...

Page 7: ... Qty Drill Size L P Gas Qty Drill Size GASVALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN V Ph Hz 4 Ampacity In Amps Max Overcurrent Protection Amps PIPE CONN SIZE IN DIMENSIONS Crated In WEIGHT Shipping Lbs Net Lbs PRODUCT SPECIFICATIONS 1 DC1D120A9601A Downflow Horizontal 120 000 112 000 92 1 40 70 DIRECT 11 x 10 1 4 See Fan Performance Table 1 2 1075 115 1 60 Centrifugal Direct 1 ...

Page 8: ... 1323 1265 1191 1095 1254 1202 1126 1032 1180 1137 1056 960 1101 1069 979 879 1016 998 896 790 TDC1C100A9481A 4 3 2 1 HIGH Black MED HIGH Blue MED LOW Yellow LOW Red 1892 1779 1630 1444 1827 1726 1587 1416 1762 1672 1544 1388 1688 1605 1485 1348 1614 1538 1426 1308 1531 1460 1362 1246 1448 1381 1297 1184 1354 1291 1208 1108 1260 1200 1119 1032 TDC1D120A9601A 4 3 2 1 HIGH Black MED HIGH Blue MED LO...

Page 9: ...9 Pub No 22 1670 10 SCHEMATIC DIAGRAMS FOR GAS FURNACES Electrical Data From Dwg D342798 ...

Page 10: ...10 Pub No 22 1670 10 SCHEMATIC DIAGRAMS FOR GAS FURNACES Electrical Data From Dwg D342798 ...

Page 11: ...B340388Rev 1 FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING COOLING OUTDOOR SECTION WITHOUT TRANSFORMER From Dwg 21B340387Rev 1 TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 ...

Page 12: ...12 Pub No 22 1670 10 Field Wiring From Dwg 21B341423Rev 1 From Dwg 21B341422Rev 1 ...

Page 13: ...601 24 1 2 2 15 16 23 1 4 23 Prefix may be A or T Notes 1 Diameter of Vent Pipe may be limited to 2 1 2 or 3 on some models at different altitudes Refer to the Vent Length Table for proper application 1 1 2 x 2 1 2 OVAL GAS CONNECTION Ø 1 5 8 HOLE WITH PLUG Ø 7 8 HOLE WITH PLUG Ø 1 5 8 HOLE WITH PLUG CONDENSATE DRAIN Ø 1 5 8 HOLE WITH PLUG GAS CONNECTION ALTERNATE 1 5 8 HOLE WITH PLUG 1 3 4 X 2 13...

Page 14: ...ce Trane has a policy of continuous product and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 www trane com 04 15 ...

Reviews: