Pub No. 18-HD55D1-1C-EN

Part No. 37-7790003

September 2020

 TCONT103
 

Installation and User Guide

       

Trane XR103 

Non-Programmable    

Heat Pump Thermostat

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit.  
These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with 
the installation. Should further information be desired or should particular problems arise which are not covered sufficiently 
for the purchaser’s purposes, the matter should be referred to your installing dealer or local distributor.

Summary of Contents for TCONT103

Page 1: ...NT This Document is customer property and is to remain with this unit These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with t...

Page 2: ...he compressor oil heaters have been operational for six hours and the system has not been operational for at least five minutes ATTENTION MERCURY NOTICE This product does not contain mercury However t...

Page 3: ...oduct Specifications 3 General Information 3 1 Overview The 103 is a non programmable HP 2H 1C thermostat with a digital display for use with HP applications only 3 2 Contents 1 Thermostat 2 Phillips...

Page 4: ...cy or auxiliary heat system requires that the thermostat energize the fan circuit do not cut jumper W906 If you are unsure of your application contact a qualified service person F or C Selection The f...

Page 5: ...heat during defrost Heat Pump with TAM Series 24V Indoor Unit Outdoor Unit Thermostat R O B Y G E C L W2 R R O O Y1 G W1 B Y0 Y2 W2 W2 W2 W3 W2 BK B X2 Y Y1 NOTES 1 Wire third party condensate overfl...

Page 6: ...it Outdoor Unit Thermostat R O B Y G E C L W2 R R O Y G W1 B W2 W2 B X2 Y NOTES 1 Wire third party condensate overflow switches between Y of the thermostat and Y1 of the airflow control board 2 X2 is...

Page 7: ...eat during defrost Heat Pump with GAT2 GAM2 TEM3 TEM4 Indoor Unit Outdoor Unit Thermostat R O B Y G E C L W2 R O G W B B X2 Y Y1 R W2 W3 NOTES 1 Wire third party condensate overflow switches between Y...

Page 8: ...en 2nd stage heat Aux or Emergency is energized Snowflake icon is displayed non flashing when the SYSTEM switch is in theCOOLposition SnowflakeandFlameiconsaredisplayed flashing if the thermostat is i...

Page 9: ...on high speed followed by cold air circulation 3 Press to adjust temperature setting above room temperature The cooling system should stop operating 6 5 Configuration Menu The configuration menu allo...

Page 10: ...ace manufacturer or a service person to verify the heating is operating correctly No Cool 1 System Switch not set to Cool 2 Loose connection to thermostat or system 3 Cooling System requires service o...

Page 11: ...Pub No 18HD55D1 1C EN 09 2020 Part No 37 7790003 11 NOTES...